36
37
Calibration Value Adjustment (GPS/GNSS disabled)
In wheel speed sensor mode the calibration value is stored as the number
of pulses produced for every kilometre/mile travelled. If you share the device
between vehicles, or change tyre sizes frequently, you may want to view and
edit this value manually.
To view the calibration value select Calibration > Value.
To edit the calibration value (only possible if GPS is disabled):
Select Calibration > Value.
1.
Press the EDIT button.
2.
Enter the new value. Use the ‘+’ and ‘-’ buttons to adjust the highlighted
3.
digit and the ‘>’ button to move between digits. When the last digit is
reached press the SET button to finish.
Advanced Features
GPS Adjustment Percentage (GPS/GNSS enabled)
By default when running from GPS/GNSS the G100+/200+ will calculate and
display the true distance travelled. However in some situations you may prefer
that the distance counters display a distance that is not the true distance
travelled. One such situation is when the rally organisers have incorrectly
calibrated their distance measuring device and therfore the event distances are
not truely correct.
With the G100+/200+ you can calibrate your rally computer to the organisers
distances by entering a percentage offset. To do this adjustment select
Calibration > GPS Adjust %
Counting Direction
The distance counters can be configured to count either up or down. To
change the direction select Settings > Advanced > Counting. You can also use
an external switch to control this setting (page 32).
Advanced Features