PROGRAMME OPTIONS EXPLAINED
AUTOMATIC (LAST DOOR) ARMING - PROGRAMMABLE

This feature is factory set in the ‘off’ position. You may have this programmed ‘on’ for added
security. The alarm will arm automatically 30 seconds after the last door is closed.

The doors will not lock so that keys cannot be locked inside

If the engine immobilises prior to the opening and closing of a door, this feature is

bypassed. Press button one to unset the immobiliser and press again to arm the system.

The opening of a door, bonnet or boot during the 30 seconds will suspend the countdown

and recommence on closure.

IGNITION SAFETY DOOR LOCK - PROGRAMMABLE

If the system has been connected to a vehicles’ central locking, the doors will lock 3 seconds after
the ignition is switched ‘on’ and unlock when the ignition is turned ‘off’.
If a door is left open for more than 3 seconds after the ignition has been turned on the safety door
lock feature will be inoperative.

SIREN CHIRPS - PROGRAMMABLE

The chirps can be permanently turned off. Only the indicators confirm the arming and disarming.

NSW SIREN TIMING – PROGRAMMABLE

It is a mandatory requirement in New South Wales, Australia, for vehicle alarm systems to sound the
siren for one trigger cycle of 30 seconds only. With this feature turned on, the indicators will flash for
any subsequent trigger.

TURBO FUNCTION – PROGRAMMABLE (not applicable to all models)

This allows an engine to remain running from a turbo timer so you can arm the bonnet, boot & doors
(and lock the doors if connected to central locking). When the turbo timer stops, the immobilisers
become active immediately and any connected sensor become active after a 10 second delay. An
intrusion through the doors whilst the engine is running will sound the alarm and immediately
immobilise the engine.

12

Summary of Contents for M60AM

Page 1: ...rtified to AS NZS4601 1999 amendment 1 2003 AS NZS3749 1 2003 Class B These products should be installed according to the requirements of the AS NZS 3749 2 Installation Standard References to alarm fu...

Page 2: ...TROL 2 Supplied BUTTON ONE ONLY ARM DISARM PRESS FOR 1 0 SECOND TO ARM OR DISARM THE SECURITY SYSTEM DOORS WILL ALSO LOCK OR UNLOCK IF THE CENTRAL LOCKING HAS BEEN CONNECTED BUTTON ONE THEN BUTTON TWO...

Page 3: ...Siren or horn output Bonnet boot doors 6 Automatic arming 2 stage impact sensor M60B 7 Ignition safety door lock Ultrasonic sensors M60AU 7 Siren chirps Microwave sensor M60AM 8 NSW siren timing Senso...

Page 4: ...the dashboard LED will slow flash as confirmation of immobilisation Only the engine is immobilised the alarm system is not yet armed If an attempt is then made to start the engine whilst immobilised t...

Page 5: ...mobilise the system The system can be programmed to arm automatically 30 seconds after the last door is closed See page 12 OPEN CIRCUIT BYPASS If any door the bonnet or boot is left open upon arming t...

Page 6: ...arming the alarm will not re arm and the doors will not re lock However the engine will re immobilise if the ignition is not turned ON within 30 seconds SILENT ARM DISARM no siren chirps Press button...

Page 7: ...ons for sensor disable by remote on page 8 ULTRASONIC SENSOR M60AU MODEL optional on other models The ultrasonic sensor fill the interior of your vehicle with high frequency sound and is designed to t...

Page 8: ...Note As the microwave produces circular protective fields some areas of the vehicle may not be protected SENSOR DISABLE BY REMOTE ALARM MODELS ONLY There are times when you may wish to deactivate the...

Page 9: ...ll then re trigger on the next intrusion If a door is left open the siren will sound for 3 x 30 seconds and then that circuit will be bypassed to avoid unnecessary noise If programmed for NSW only sou...

Page 10: ...lash codes a Fast flashing 30 second countdown of automatic functions b Slow flashing system armed c LED off system off d On permanently in remote code learning mode e 1 flash bonnet or boot has been...

Page 11: ...cle s electric boot release f the vehicle is equipped This may incur additional charges depending on the vehicle specification To activate Press button two on the remote for 3 seconds and the boot wil...

Page 12: ...turned off If a door is left open for more than 3 seconds after the ignition has been turned on the safety door lock feature will be inoperative SIREN CHIRPS PROGRAMMABLE The chirps can be permanentl...

Page 13: ...s the alarm module can memorise up to four remote controls The batteries in the remote controls should be changed when you notice any of the following System does not respond to the remote signal Oper...

Page 14: ...chirp twice as confirmation of reception Repeat for up to four remotes siren will chirp 3 times for the third and 4 times for the fourth Leave the system for 10 seconds and the learning mode is compl...

Page 15: ...er The LED will light 6 Ignition OFF count the number of flashes 7 Ignition ON after 2 flashes 3rd number The LED will light 8 Ignition OFF count the number of flashes 9 Ignition ON after 5 flashes 4t...

Page 16: ...siren 3 Enter the vehicle and shut all doors arm the system by remote and try to start the engine to test the engine immobiliser it should not start 4 To test the ultrasonic sensors M60AU enter the v...

Page 17: ...RIGGER jumper changes polarity 6 NO CONNECTION 10 FLASHER INDICATOR OUTPUT 8 amp cont max 11 12V CONSTANT 12v POWER SUPPLY 12 FLASHER INDICATOR OUTPUT 8 amp cont max 13 14 GND 2 GROUNDS DO NOT JOIN TO...

Page 18: ...WIRING...

Page 19: ...sensor port is a 4 pin input that accepts an impact sensor ultrasonic sensor or microwave sensor A Y connector is available as an option where 2 sensors are required The M60B M60S is supplied with a 2...

Page 20: ...RASONIC SENSOR M60AU optional on other models Ultrasonic s will detect any movement inside the car including air movement It is therefore important that all windows vents and sunroofs be fully closed...

Page 21: ...rk with windows down sunroofs open or even in a convertible with the top down Air movement noise and temperature should not affect the microwave The two field sizes are independently adjustable from t...

Page 22: ...misuse accident deliberate act or abuse eg misdirected electrical current ingress of water or fluid vehicle damage Exclusions I removal refitting costs of parts ii mobile service costs iii batteries...

Page 23: ...t including setting and unsetting facilities all sensors warning devices and provision for immobilisation of the vehicle Whilst this security system provides a deterrent it may not prevent theft or da...

Page 24: ......

Page 25: ...TURE Please complete the above details detach from this manual and keep in a safe place These details should be presented to your Mongoose dealer in the unlikely event that you require this product to...

Reviews: