background image

BUTTON ‘TWO’ ONLY

CH2 OUTPUT

PRESS FOR 3 SECONDS FOR
‘AUXILIARY OUTPUT’ (EG: BOOT
RELEASE)

BUTTON ‘TWO’
THEN
BUTTON ‘ONE’

SILENT ARM / DISARM

THIS SEQUENCE WILL SILENTLY
ARM OR DIS-ARM THE SYSTEM
WITHOUT SIREN CHIRPS.

ALARM MODELS ONLY

BUTTON ‘ONE’ AND ‘TWO’ TOGETHER

‘PANIC’

PRESS FOR 3 SECONDS TO SOUND
THE SIREN OF THE ALARM. PRESS
BOTH AGAIN TO CANCEL

REMOTE CONTROL

2 Supplied

BUTTON ‘ONE’ ONLY

ARM & DISARM

PRESS FOR 1.0 SECOND
TO ARM OR DISARM THE
SECURITY SYSTEM -
(DOORS WILL ALSO LOCK OR
UNLOCK IF THE CENTRAL
LOCKING HAS BEEN
CONNECTED)

BUTTON ‘ONE’ THEN
BUTTON ‘TWO’

‘SENSOR BYPASS’

THIS SEQUENCE DEACTIVATES
SENSORS SUCH AS THE IMPACT SENSOR, ULTRASONIC’S OR MICROWAVE (DEPENDING ON
MODEL). DOORS, BONNET & BOOT REMAIN PROTECTED.

ONLY DEACTIVATE SENSORS TO
REDUCE THE POSSIBILITY OF FALSE ALARMS.

BATTERY REPLACEMENT

YOUR REMOTE CONTROL USES ONE 12v 23amp BATTERY WHICH

IS AVAILABLE FROM YOUR MONGOOSE AGENT OR ELECTRONIC SHOP.

CHANGE AT LEAST ONCE A YEAR.

Summary of Contents for M60AM

Page 1: ...rtified to AS NZS4601 1999 amendment 1 2003 AS NZS3749 1 2003 Class B These products should be installed according to the requirements of the AS NZS 3749 2 Installation Standard References to alarm fu...

Page 2: ...TROL 2 Supplied BUTTON ONE ONLY ARM DISARM PRESS FOR 1 0 SECOND TO ARM OR DISARM THE SECURITY SYSTEM DOORS WILL ALSO LOCK OR UNLOCK IF THE CENTRAL LOCKING HAS BEEN CONNECTED BUTTON ONE THEN BUTTON TWO...

Page 3: ...Siren or horn output Bonnet boot doors 6 Automatic arming 2 stage impact sensor M60B 7 Ignition safety door lock Ultrasonic sensors M60AU 7 Siren chirps Microwave sensor M60AM 8 NSW siren timing Senso...

Page 4: ...the dashboard LED will slow flash as confirmation of immobilisation Only the engine is immobilised the alarm system is not yet armed If an attempt is then made to start the engine whilst immobilised t...

Page 5: ...mobilise the system The system can be programmed to arm automatically 30 seconds after the last door is closed See page 12 OPEN CIRCUIT BYPASS If any door the bonnet or boot is left open upon arming t...

Page 6: ...arming the alarm will not re arm and the doors will not re lock However the engine will re immobilise if the ignition is not turned ON within 30 seconds SILENT ARM DISARM no siren chirps Press button...

Page 7: ...ons for sensor disable by remote on page 8 ULTRASONIC SENSOR M60AU MODEL optional on other models The ultrasonic sensor fill the interior of your vehicle with high frequency sound and is designed to t...

Page 8: ...Note As the microwave produces circular protective fields some areas of the vehicle may not be protected SENSOR DISABLE BY REMOTE ALARM MODELS ONLY There are times when you may wish to deactivate the...

Page 9: ...ll then re trigger on the next intrusion If a door is left open the siren will sound for 3 x 30 seconds and then that circuit will be bypassed to avoid unnecessary noise If programmed for NSW only sou...

Page 10: ...lash codes a Fast flashing 30 second countdown of automatic functions b Slow flashing system armed c LED off system off d On permanently in remote code learning mode e 1 flash bonnet or boot has been...

Page 11: ...cle s electric boot release f the vehicle is equipped This may incur additional charges depending on the vehicle specification To activate Press button two on the remote for 3 seconds and the boot wil...

Page 12: ...turned off If a door is left open for more than 3 seconds after the ignition has been turned on the safety door lock feature will be inoperative SIREN CHIRPS PROGRAMMABLE The chirps can be permanentl...

Page 13: ...s the alarm module can memorise up to four remote controls The batteries in the remote controls should be changed when you notice any of the following System does not respond to the remote signal Oper...

Page 14: ...chirp twice as confirmation of reception Repeat for up to four remotes siren will chirp 3 times for the third and 4 times for the fourth Leave the system for 10 seconds and the learning mode is compl...

Page 15: ...er The LED will light 6 Ignition OFF count the number of flashes 7 Ignition ON after 2 flashes 3rd number The LED will light 8 Ignition OFF count the number of flashes 9 Ignition ON after 5 flashes 4t...

Page 16: ...siren 3 Enter the vehicle and shut all doors arm the system by remote and try to start the engine to test the engine immobiliser it should not start 4 To test the ultrasonic sensors M60AU enter the v...

Page 17: ...RIGGER jumper changes polarity 6 NO CONNECTION 10 FLASHER INDICATOR OUTPUT 8 amp cont max 11 12V CONSTANT 12v POWER SUPPLY 12 FLASHER INDICATOR OUTPUT 8 amp cont max 13 14 GND 2 GROUNDS DO NOT JOIN TO...

Page 18: ...WIRING...

Page 19: ...sensor port is a 4 pin input that accepts an impact sensor ultrasonic sensor or microwave sensor A Y connector is available as an option where 2 sensors are required The M60B M60S is supplied with a 2...

Page 20: ...RASONIC SENSOR M60AU optional on other models Ultrasonic s will detect any movement inside the car including air movement It is therefore important that all windows vents and sunroofs be fully closed...

Page 21: ...rk with windows down sunroofs open or even in a convertible with the top down Air movement noise and temperature should not affect the microwave The two field sizes are independently adjustable from t...

Page 22: ...misuse accident deliberate act or abuse eg misdirected electrical current ingress of water or fluid vehicle damage Exclusions I removal refitting costs of parts ii mobile service costs iii batteries...

Page 23: ...t including setting and unsetting facilities all sensors warning devices and provision for immobilisation of the vehicle Whilst this security system provides a deterrent it may not prevent theft or da...

Page 24: ......

Page 25: ...TURE Please complete the above details detach from this manual and keep in a safe place These details should be presented to your Mongoose dealer in the unlikely event that you require this product to...

Reviews: