locating fireplace
NOT
E
cOLD cLIMAtE INSuLAtION
If you live in a cold climate, seal all cracks around your appliance, and wherever cold air could enter
the room, with noncombustible material. It is especially important to insulate the outside chase cavity
between the studs and under the floor on which the appliance rests, if the floor is above ground level.
BDV Series Gas Fireplace
pRE-INStALLAtION INFORMAtION
FIREpLAcE LOcAtION
Plan for the installation of your appliance. This includes determining where the unit is to be installed,
the vent configuration to be used, framing and finishing details, and whether any optional accessories
(i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to
ensure compliance with local codes, including permits and inspections.
The following factors should be taken into consideration:
• Clearance to side-wall, ceiling, woodwork, and windows. Minimum clearances to combustibles
must be maintained.
• This fireplace may be installed along a wall, across a corner, or use an exterior chase.
See Figure
4
for suggested locations.
• Location should be out of high traffic areas and away from furniture and draperies due to heat
from appliance.
• Never obstruct the front opening of the fireplace.
• Do
not
install in the vicinity where gasoline or other flammable liquids may be stored.
• Vent pipe routing. See
Venting
section found in this manual for allowable venting configura-
tions.
• These units can be installed in a bedroom. See National Fuel Gas Code ANSI Z233.1/NFPA 54
— (current edition), the Uniform Mechanical Code — (current edition), and Local Building Codes
for specific installation requirements.
Figure 4 - Locating Gas Fireplace
A Flat on Wall
B Cross Corner
C Island**
D Room Divider*
E Flat on Wall Corner*
F Chase Installation
Y 4" Minimum
** Island (C) and room divider (D) installation is possible as long as the horizontal portion of vent
system (X) does not exceed 20'. See
Installing Horizontal Termination Configuration
on pages
18 and 19.
* When you install your fireplace in (D) room divider or (E) flat on wall corner positions (Y), a
minimum of 6" clearance must be maintained from perpendicular wall and front of fireplace.