54D0700
51
BDV Series Gas Fireplace
tROuBLEShOOtING
StANDING pILOt IGNItION
SyMptOM
pOSSIBLE cAuSE
ActION
1. Spark ignitor will
not light pilot after
repeated triggering of
piezo.
2. Pilot will not stay lit
after carefully follow-
ing lighting instruc-
tions.
3. Pilot burning, valve
knob turned to “ON”,
switch is turned to
“ON” or “RS”, but
burner will not ignite.
A. Wire disconnected.
B. Defective ignitor.
C. No gas or low gas pres-
sure.
D. No Propane/LPG in tank
A. Defective thermocouple
B. Defective valve
A. Defective switch, wall
switch, remote control or
wire
B. Pilot flame too small
C. Defective or malfunction-
ing thermopile
D. Defective valve
A. Open door and check to make sure wire is connected to
ignitor.
B. Check for spark at electrode and pilot. If no spark and
electrode wire is properly connected, replace pilot assem-
bly.
C. Check remote/manual shut off valve from fireplace. Low
pressure can be caused by bent lines, restricted lines, low
pressure line pressure. Consult with plumber or gas sup-
plier.
D. Check Propane/LPG tank. Refill tank.
A. Check that thermocouple flame impinges on thermocou-
ple. Clean and/or adjust pilot for maximum flame impinge-
ment. Ensure that the thermocouple connection at the gas
valve is fully inserted and tight.
Disconnect the thermocouple from the valve, place one
millivolt lead wire on the tip of the thermocouple and the
other meter lead wire on the thermocouple copper lead.
Start the pilot and hold the valve knob in. If the millivolt
reading is less than 15 mV, replace pilot assembly.
B. If thermocouple is producing more than 15 mV, replace
faulty valve.
A. Check switch and wire for proper connection. Place
jumper wires across terminals of switch. If burner comes
on, replace defective switch.If the switch is OK, repeat the
same procedure on remote control If burner comes on,
replace remote control.
Place jumper wire across wire at gas valves (terminals
marked TH and TP/TH). If burner comes on, wires are
faulty or connections are bad. Replace wire.
B. If pilot flame is not close enough to the thermopile, adjust
pilot flame.
C. Check thermopile wire connections to make sure all are
tight and that the thermopile is fully inserted into pilot
assembly. Check thermopile with a millivolt meter. Con-
nect leads to TP and TP/TH terminals on the control valve.
If meter reading is below 325 mV, replace pilot assembly.
D. Turn valve knob to “On” and switch to “ON.” Take a read-
ing at the thermopile leads (TP & TP/TH) on the valve. If
the meter reads greater than 175 mV and the burner does
not light, replace defective valve.