background image

6

All repair part orders should be placed through your local dealer.  To ensure prompt and accurate service, please
provide the following information when placing a repair part order:  Model number of your Appliance, Part Name,
Part Number, and Quantity of parts needed.  D

O

 

NOT

 

TAKE

 

A

 

HEATER

 

NEEDING

 

REPAIR

OR

 

BELIEVED

 

TO

 

BE

 

DEFECTIVE

BACK

 

TO

THE

 

SELLER

.

P

ARTS

  L

IST

3

53D9013. Rev 1 03/03

KEY

NO.

1
2
3
4
5
6

 7
 8
 9

10

11

12

13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

33
34
35

36
37
38

39
40

 
Cabinet Back Pntd.
Speed Nut 10-24 U Type
Cabinet Top W/Caution Label
Cabinet Side Left W/Labels
Piezo Cable
Cabinet Front Pntd.
Screw 10-24 x Ω  Phillips, Pntd.
Front Glass
Dress Guard Pntd.
Bottom Shield
Right Burner Bracket Pntd.
Pilot Bracket Assembly, LP Gas
Pilot Bracket Assembly, NAT Gas
Left Burner Bracket Pntd.
Wall Anchor
Control Shield
Piezo Ignitor
Nut Mounting
Control Bracket Assembly Pntd.
Control Knob
Control Ring
Cabinet Side Right W/Markings
Manual Control
Steel Ball 5/16" Dia.
1/4" Compression Nut
Heat Shield
Chamber Top Pntd.
Chamber Pntd.
Hearth Plate Pntd.
Elbow, 1/2 FNPT x 3/8 CC (No Nut)
Pilot Tube Assembly
Elbow, 3/8 NPT x 3/8 CC (No Nut)
Pilot LP Gas 
Pilot NAT Gas
Burner Manifold Tube Assembly
Split Nut, Brass
Orifice LP Gas
Orifice NAT Gas
Burner Assembly
Inlet Fitting Assembly Pntd.
Regulator LP Gas
Regulator NAT Gas
Regulator to Control Tube Assembly
Ell Street, 3/8 NPT 

1
1
5
1
1
1
1
2
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

BFVF1M

PART NO.

078070
050889
074034
078079
067972
072527
051075
072553
072510
063227
062165
061518
061451
062164
052997

071040
026058
075536
074028
051044
078073
032965
052647
032954
061399
075281
062564
062163

072486

14D0476
26D2529

072476
075534
062146

P4903

062175
072495
072499
072500
072481

P1028

BFVF2M

PART NO.

078071
050889
074035
078080
067972
072337
051075
061420

072511

063226
062165
061518
061451
062164
052997

071040
026058
074029
074028
076075
078073
026174

061046
075282
062565
062358
072558
072487
072557

14D0476
26D2529

072477
075534
049198
038247
062377
072495
072499
072500
072482

P1028

BFVF3M

PART NO.

078072
050889
074036
078080
067972
072344
051075
072549
072512
063225
072538
061518
061451
072536
052997
072540
071040
026058
074029
074028
076075
078073
026174

072535
075283
072545
072543
072558
072488
072557

14D0476
26D2529

072478
075534
032743
067382
061450
072554
072088
072086
072483

PART NAME

QTY.

Summary of Contents for BFVF1M

Page 1: ...CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FO...

Page 2: ...ILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE HEATER ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV...

Page 3: ...ing damage and missing parts If any damage or missing parts are detected report this to the dealer from whom you purchased the heater and get the deficiency corrected before installing and using the h...

Page 4: ...B GLASS IN TOP TAB GLASS IN PROPER POSITION PROPER POSITION WILL BE IN FRONT WILL BE IN FRONT FOR SHIPPING FROM FOR SHIPPING FROM CENTER TAB GLASS CENTER TAB GLASS IN PROPER POSITION IN PROPER POSITIO...

Page 5: ...t Tube Assembly Elbow 3 8 NPT x 3 8 CC No Nut Pilot LP Gas Pilot NAT Gas Burner Manifold Tube Assembly Split Nut Brass Orifice LP Gas Orifice NAT Gas Burner Assembly Inlet Fitting Assembly Pntd Regula...

Page 6: ...STALLATION AND ADJUSTMENT or TROUBLESHOOTING sections of this manual The control system on this heater serves several functions It regulates the incoming gas to the correct pressure for the combustion...

Page 7: ...e minimum clearances see Figure 1 between combustible materials and a wall mounted heater are Back 0 inches mount directly on wall Floor 3 inches Sides 4 inches on each side of the heater Top 36 inche...

Page 8: ...be installed in a bedroom If a blue flame heater is installed in a bedroom it must be wall mounted Floor stand mounted heaters are prohibited in bedrooms FLOOR PROTECTION Some Flooring materials will...

Page 9: ...aded joints of gas piping must be resistant to the action of liquefied petroleum gas Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7 inches water...

Page 10: ...NSTALLED AS A FREESTANDING HEATER AS A FREESTANDING HEATER FLOOR STAND SOLD AS AN ACCESSORY FLOOR STAND SOLD AS AN ACCESSORY FLOOR PROTECTION REQUIRED FLOOR PROTECTION REQUIRED FOR ANY COMBUSTIBLE FLO...

Page 11: ...put rating of all gas fired appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8m per kW of the aggregate input...

Page 12: ...ve off carbon monoxide an odorless poisonous gas If this heater shuts off during operation do not relight it until you provide additional fresh air If permanent provisions for providing additional fre...

Page 13: ...wers acceptable for use on these heaters The use of any other blower could adversely and dangerously affect the operation of these heaters The blower should be installed on the heater before the heate...

Page 14: ...TO WALL STUDS NOT DRIVE ANCHORS INTO WALL STUDS FLAT SURFACES OF ANCHOR BLADES FLAT SURFACES OF ANCHOR BLADES MUST BE PARALLEL TO THE FLOOR MUST BE PARALLEL TO THE FLOOR DO NOT INSTALL ANCHOR WITH FLA...

Page 15: ...s on back of the heater Insert two screws from the bag of fasteners through the holes in the standoffs Tighten the screws into the wall until the heater is firmly secured to the wall See Figure 6 Proc...

Page 16: ...do the following Turn the gas off at the shutoff valve Loosen the four screws which secure the control s mounting bracket Item No 23 of PARTS DIAGRAM found in the upper right hand corner of the heater...

Page 17: ...er s control knob to Pilot Allow the main burner to cool Reinstall the heater s front panel See Figure 6 As the front panel is being installed verify that the glass is in it s proper position in the w...

Page 18: ...knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use th...

Page 19: ...ill not stay lit after several tries turn the gas control knob clockwise to OFF and call your service technician or gas supplier 7 When the pilot is lit and burning steadily depress the control knob s...

Page 20: ...stible materials gasoline and other flammable liquids 9 Do take the necessary precautions during any pressure testing of the heater s gas supply piping system 10 Do keep children and mentally impaired...

Page 21: ...UT THE FACTORY INSTALLED DRESS GUARD IN PLACE ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE The pilot gas flow is not adjustable on th...

Page 22: ...r replacements must be performed by a qualified person Do not replace any component with a different type Only use components supplied by the manufacturer of this heater 20 Control knob binds Won t po...

Page 23: ...nsequential damages so the above limitation or exclusion may not apply to you 4 This warranty applies only to the original purchaser and may not be transferred 5 This warranty applies only to a gas he...

Page 24: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9013 REV 1 03 03...

Reviews: