Use these instructions as a guide
while installing and adjusting the
heater. The installation must
conform with local codes or, in
the absence of local codes, with
the latest edition of the National
Fuel Gas Code ANSI Z223.1/
NFPA 54.
11
Use these instructions as a guide while installing and adjusting the heater.
The installation must conform with local codes or, in the absence of local
codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1/
NFPA 54.
If your heater is to be installed as a wall mounted heater begin with Step
1. If your heater is to be installed as a freestanding heater, begin with
Step 10.
O
PTIONAL
B
LOWERS
A model XAB theromstatically controlled, or model XMB manually
controlled, blower may be installed on the 20,000 and 30,000 Btu heaters.
(BFVF1M models are not designed for use with optional blowers.) These
blowers are the only blowers acceptable for use on these heaters. The
use of any other blower could adversely and dangerously affect the
operation of these heaters. The blower should be installed on the heater
before the heater is installed. Check with your dealer for additional
information and to purchase an optional blower.
W
ALL
M
OUNTED
H
EATER
1. Locate the wall-mount template and bag of fasteners provided with
the heater.
2. Tape the wall-mount template to the wall surface where the heater
is to be located. Template locator points should be level. Figure 4.
3. Check minimum clearances to combustible materials as directed
by the wall-mount template. Refer to Figure 1 for additional
information.
F
IGURE
4
TEMPLATE
NOTE: DO NOT LOCATE WALL-MOUNT TEMPLATE WHERE LOCATOR
NOTE: DO NOT LOCATE WALL-MOUNT TEMPLATE WHERE LOCATOR
POINTS ON TEMPLATE WILL ALIGN WITH STUDS IN WALL.
POINTS ON TEMPLATE WILL ALIGN WITH STUDS IN WALL.
LOCATOR POINTS
LOCATOR POINTS
(SEE NOTE)
(SEE NOTE)
LOCATE TEMPLATE ON WALL AS
LOCATE TEMPLATE ON WALL AS
DIRECTED BY TEMPLATE.
DIRECTED BY TEMPLATE.
FLOOR
FLOOR
SIDE WALL
SIDE WALL
53D9013. Rev 1 03/03