background image

OWNERS
MANUAL

  

MJSE

Jet Sprinkler Pump

296515eR6     0503

5' lift

  10' lift

15' lift

20' lift

25' lift

1.5  lift

3.0  lift

4.5  lift

6.0  lift

7.5  lift

11.2

10.4

9.4

7.6

5.3

42.4

39.4

35.6

28.8

20.1

PERFORMANCE

   Pump

Discharge

U.S. Gallons per minute,

Litres per minute,

H.P.

Pressure

at static lift in feet below

at static lift in meters below

1/2

  40

INSTALLATION

a)

Pump Location:

 The pump should be installed in a clean, dry and

ventilated location which provides adequate room for servicing and
protection from freezing temperatures.  It should be bolted to a good
foundation, preferably concrete and provided adequate drainage.
Locating the pump as close as possible to the water source reduces
the friction in the suction pipe and will give maximum capacities.

b)

Suction pipe:

  It  is recommended that only new, clean 1-1/4 inch

pipe or hose be used.  If the pump is installed any appreciable
distance  away from the source of water,  the suction pipe should be
increased to 1-1/2 inch.  Horizontal lengths of pipe must gradually
slope upwards from the source of water to the pump to avoid air
pockets in the line.  Thread compound should be used on all pipe

joints and connections should be thoroughly  tightened.  A foot
valve must be installed and its operation should be checked
since a leak will prevent proper operation of the system.  Make
sure that the foot valve is located so that it will be submerged at
all times.  If a sand point or driven well is used, install a check
valve next to the pump suction instead of the foot valve.  For
booster pump applications no foot valve is required.

c)

Service Line: 

 The service line should be connected as shown

in Fig. 1.  The size of the service line required is governed
entirely by the amount of water needed and the length of the
pipe.  The pipe selected should be large enough so that the
friction loss (determined fromTable 2, Friction Loss Chart) will
never exceed a 20 ft. (6m) head.

APPLICATION

This jet sprinkler pump is a versitile  pump for pressure boosting:
small underground sprinkler systems: operating lawn sprinklers and
a multitude of other general purpose applications.  This pump is
suitable for installations where the vertical distance from the pump

to the water level does not exceed *25 ft. (7.6m), including
drawdown.   In offset installations, friction  losses  in  the suction pipe
must be taken into consideration. (Refer to Table 2, Friction loss
Chart).
*Less at high altitudes.

 

WARNING - ELECTRICAL PRECAUTIONS

All wiring, electrical connections, and system grounding
must comply with the National Electrical Code (NEC) and
with any local codes and ordinances.  Employ a licensed
electrician.

 

WARNING -  RISK OF ELECTRICAL SHOCK

.

This pump is supplied with a grounding conductor and grounding
type attachment plug.

.

To reduce risk of electrical shock, 

be certain that it is connected

only to a properly grounded, grounding-type receptacle.

.

A ground fault interrupter (GFI) protected circuit is recommended for
use with any electrical device operating near water.

.

Have an electrician provide an outlet near the point of use.  For
recommended cable size see table 1.

.

Pump and motor must be protected from the weather, for indoor use
only.

.

Motor must be grounded and terminal cover in place to reduce
electrical shock hazard.

.

Keep motor operating area as dry as possible.

.

Always disconnect power before servicing.

.

Not investigated for use in swimming pool area.

SAFETY  WARNINGS

BEFORE  OPERATING  OR
INSTALLING  THIS  PUMP,  READ
THIS  MANUAL  AND  FOLLOW  ALL
SAFETY  RULES  AND  OPERATING
INSTRUCTIONS.

 

     FOR DUAL VOLTAGE MOTORS:

Voltage change instructions are located on motor label or on

wiring access cover.

Summary of Contents for MJSE

Page 1: ...y by the amount of water needed and the length of the pipe The pipe selected should be large enough so that the friction loss determined fromTable 2 Friction Loss Chart will never exceed a 20 ft 6m head APPLICATION This jet sprinkler pump is a versitile pump for pressure boosting small underground sprinkler systems operating lawn sprinklers and a multitude of other general purpose applications Thi...

Page 2: ...8 3 10 1 46 43 16 48 6 15 1 3 96 1 87 55 18 60 5 18 7 4 93 2 33 69 20 73 5 22 8 6 00 2 83 84 Loss of head in meters due to friction per 100 meters of pipe Nominal Pipe Size 20mm 25mm 32mm 40mm 50mm L Min 15 3 7 1 15 0 30 0 13 20 5 3 1 64 0 43 0 19 25 7 1 2 18 0 56 0 27 30 13 5 4 13 1 08 0 49 35 16 3 5 00 1 31 0 61 40 23 5 7 30 1 90 0 88 0 25 45 28 3 8 74 2 31 1 07 0 29 50 34 2 10 6 2 79 1 32 0 38 ...

Page 3: ...e turned by hand insert a flat object into the impeller vane 7 Slip the rotating seal 7 off the shaft and remove the seal plate 8 8 Remove the ceramic seal seat 9 from the seal plate Fig 2 Reassembly 1 Clean all the parts thoroughly before assembling 2 Push ceramic seal 9 it into the seal plate using thumbs only Make sure the smooth surface of the ceramic seat faces outwards 3 Put the seal plate b...

Page 4: ...FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM PURCHASE AND TO THE EXTENT PERMITTED BY LAW LIABILITY FOR CONSEQUENTIAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW This warranty is an addition to any statutory warranty TROUBLES SHOOTING GUIDE a Motor will not start 1 No power due to blown fuses open switches or loose connec tions b Pump fails...