background image

2

TABLE 1

 

CAUTION

Undersize wire between the motor and the power source will adversely limit the
starting  and load carrying abilities of the motor.  Minimum wire sizes for the
motor branch circuits are recommended in table 1.

Recommended Wire Gauge For

Electrical Cord Length

HP

Volts

0-25 ft.

50ft.

100ft.

150ft

200ft.

1/2

115

14

12

10

8

6

TABLE 2–  FRICTION LOSS CHART FOR PLASTIC PIPE:

For galvanized pipe, double the figures.
Loss of head in feet, due to friction per 100 feet of pipe.

Nominal
Pipe Size

3/4"

1"

1-1/4"

1-1/2"

2"

U.S. GPM

4

3.75

1.15

.30

.14

5

5.66

1.75

.46

.22

6

7.95

2.45

.65

.31

7

10.6

3.25

.86

.41

8

13.5

4.16

1.10

.52

9

16.8

5.17

1.35

.65

10

20.4

6.31

1.67

.79

.23

11

24.4

7.58

1.98

.95

.27

12

28.6

8.85

2.33

1.10

.32

14

38.0

11.8

3.10

1.46

.43

16

48.6

15.1

3.96

1.87

.55

18

60.5

18.7

4.93

2.33

.69

20

73.5

22.8

6.00

2.83

.84

Loss of head in meters, due to friction per 100 meters of pipe.

Nominal
Pipe Size

20mm

25mm

32mm

40mm

50mm

L/Min.

15

3.7

1.15

0.30

0.13

 20

5.3

1.64

0.43

0.19

 25

7.1

2.18

0.56

0.27

 30

13.5

4.13

1.08

0.49

35

16.3

5.00

1.31

0.61

40

23.5

7.30

1.90

0.88

0.25

45

28.3

8.74

2.31

1.07

0.29

50

34.2

10.6

2.79

1.32

0.38

55

40.7

12.6

3.32

1.56

0.46

60

48.1

14.9

3.92

1.85

0.54

65

55.7

17.3

4.45

2.15

0.63

70

63.8

19.7

5.20

2.46

0.73

75

72.2

22.4

5.89

2.78

0.83

1-1/4" Suction
Hose

Foot Valve

Priming Plug

Street Tee (not
included)

Garden Hose Adaptor
(included)

To Sprinkler System

Garden Hose

Weather Proof Enclosure

To 115v
Grounded Outlet

Base

To Sprinkler
 System

Handle

To 115v
Grounded
 Outlet

Base

INSTALLATION

ALTERNATE INSTALLATION AS A BOOSTER PUMP

Garden Hose

Street Tee
 (not included)

1-1/4"
Suction Hose

Garden Hose Adaptor (included)

Fig. 1

Summary of Contents for MJSE

Page 1: ...y by the amount of water needed and the length of the pipe The pipe selected should be large enough so that the friction loss determined fromTable 2 Friction Loss Chart will never exceed a 20 ft 6m head APPLICATION This jet sprinkler pump is a versitile pump for pressure boosting small underground sprinkler systems operating lawn sprinklers and a multitude of other general purpose applications Thi...

Page 2: ...8 3 10 1 46 43 16 48 6 15 1 3 96 1 87 55 18 60 5 18 7 4 93 2 33 69 20 73 5 22 8 6 00 2 83 84 Loss of head in meters due to friction per 100 meters of pipe Nominal Pipe Size 20mm 25mm 32mm 40mm 50mm L Min 15 3 7 1 15 0 30 0 13 20 5 3 1 64 0 43 0 19 25 7 1 2 18 0 56 0 27 30 13 5 4 13 1 08 0 49 35 16 3 5 00 1 31 0 61 40 23 5 7 30 1 90 0 88 0 25 45 28 3 8 74 2 31 1 07 0 29 50 34 2 10 6 2 79 1 32 0 38 ...

Page 3: ...e turned by hand insert a flat object into the impeller vane 7 Slip the rotating seal 7 off the shaft and remove the seal plate 8 8 Remove the ceramic seal seat 9 from the seal plate Fig 2 Reassembly 1 Clean all the parts thoroughly before assembling 2 Push ceramic seal 9 it into the seal plate using thumbs only Make sure the smooth surface of the ceramic seat faces outwards 3 Put the seal plate b...

Page 4: ...FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM PURCHASE AND TO THE EXTENT PERMITTED BY LAW LIABILITY FOR CONSEQUENTIAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW This warranty is an addition to any statutory warranty TROUBLES SHOOTING GUIDE a Motor will not start 1 No power due to blown fuses open switches or loose connec tions b Pump fails...

Reviews: