WATER SYSTEMS - 6
CAYMAN 2007
122
Waste Pump (Optional)
The waste pump is a self-priming impeller
pump designed to minimize clogging when
draining the tanks.
To Empty the Black Tank:
Secure the macerator pump to the dump
connection. Secure the waste pump
outlet hose.
Remove the drip cap at the bottom of the
sewer pipe adapter.
Insert the adapter into the sewer
connection.
Open the solid (black) waste drain valve
at the plumbing service center.
Turn on the macerator pump using the
switch on the service center panel.
Turn off the pump when the black tank is
empty.
To Flush the Black Tank:
Insert the sewer pipe adapter in the
facility sewer connection.
Open the solid waste drain valve. Close
the liquid waste drain valve. Fill the grey
tank at least 50% full.
Connect a non-potable water hose with
pressure regulator to the fl ush system
fi tting in the plumbing service center.
Turn on the water supply and waste
pump. Allow the water to rinse the black
tank for at least three minutes. Never
operate the system unattended. The
water must fl ow freely through the waste
pump outlet hose.
When completed turn off the faucet.
Close the solid waste drain valve and
open the liquid waste drain valve. Turn
on the waste pump. The water in the
grey tank will fl ush the remaining solids
from the sewer hose. The liquid waste
drain valve remains open until the next
drain cycle or time of departure.
When Preparing for Travel:
Empty the tanks and close both the
solid and liquid waste drain valves.
Undo restraining devices from the waste
pump outlet hose. Drain the hose using
a hand over hand method while working
the hose toward the shore connection.
Remove sewer pipe adapter from shore
fi tting and install drip cap. Coil and store
hose in water bay.
If desired, add chemical to the tanks to
control odor. Follow the directions given
by the manufacturer of the chemical.
NOTE:
Drain both waste tanks before traveling.
Troubleshooting:
The house battery disconnect switch
(in battery compartment) must be on to
operate the macerator pump.
12 Volt DC power for the macerator
pump is supplied by the house batteries
and is protected with a 20 Amp mini
breaker located in the battery bay.
TOILET
Operating
Instructions
The toilet
operates
from either
the fresh water tank or city water supply. The
water pump must be turned on or the city water
connected. The toilet fl ushes directly into a
sewage holding tank (black water).
Insert hose end into
sewer connection.
040516L
040516j
Sewer hose end with adapter.
040416
Summary of Contents for CAYMAN 2007
Page 12: ...GENERAL INFORMATION 1 CAYMAN 2007 8 NOTES...
Page 14: ......
Page 16: ......
Page 52: ...DRIVING SAFETY 2 CAYMAN 2007 48 NOTES...
Page 80: ...EXTERIOR INTERIOR CARE 3 CAYMAN 2007 76 NOTES...
Page 100: ...APPLIANCES 4 CAYMAN 2007 96 NOTES...
Page 132: ...WATER SYSTEMS 6 CAYMAN 2007 128 NOTES...
Page 160: ...ELECTRICAL SYSTEMS HOUSE 8 156 CAYMAN 2007 NOTES...
Page 226: ...INDEX 222 CAYMAN 2007 NOTES...