WATER SYSTEMS - 6
CAYMAN 2007
117
The water pump can be
either off or on. It will not
affect the water pump to
leave it ON.
The City Water Hook-up
in the service center has a
built in pressure regulator
and one-way check valve.
The pressure regulator
limits the water pressure to
approximately 45 psi.
CAUTION:
Some outside water sources develop
high water pressure, particularly in
mountainous regions. High water
pressure is anything over 55 psi (pounds
per square inch). Excess pressure on
a hot day can cause the water hose to
swell and burst. Excess pressure on
a hot day can cause the water hose to
swell and burst. An additional pressure
regulator can be connected to the city
water faucet to regulate the pressure to
the potable water hose.
WATER PUMP
The water pump pressurizes the fresh water
system when not connected to city water.
The water pump is self-priming, operating on
demand as water is used. The water pump is
located behind the water service panel. Access
the water pump by removing an access panel in
the pass-through storage bay next to the water
service center.
WARNING:
Before leaving the motorhome for
extended periods of time (i.e. overnight
or longer) be sure that the city water
supply and water pump have been
turned off. Damage from neglect will be
the responsibility of the owner, not the
manufacturer.
The water pump can be operated from the
following locations:
Hallway Monitor Panel
Water service bay
To turn the water pump ON or OFF:
Momentarily press the water pump
switch. The indicator lamp will
illuminate when the water pump is
turned on.
CAUTION:
DO NOT continue water pump
operation if the fresh water holding
tank is empty. Damage to the water
pump or electrical supply system may
result.
To operate the water pump:
Close all drain
valves and low point
drains.
Fill the fresh water
tank.
Open the hot and
cold water valves of
each faucet.
Turn the water pump
ON
. Wait for the
water lines and the
hot water tank to fi ll.
Close each faucet when it delivers a
steady stream of water (cold water
faucets fi rst).
Water Pump Troubleshooting
Vibration induced by road conditions can
cause the plumbing or pump hardware to loosen.
Check the water pump system for components
that are loose. Many symptoms can be resolved
by tightening the hardware. Check the following
items:
Water pump will not start or blows the
fuse:
Check the electrical connections, fuse
or breaker, main switch and ground
connection.
Is voltage present at the pressure switch
on the pump? If voltage is present, the
pressure switch may be faulty. As a test,
temporarily bypass the pressure switch.
Check the charging system for correct
voltage and good ground.
Water Pump Operation
040487r
Monitor Panel water
pump switch located
in hallway.
waTer
PuMP
PuMP
sTaTus
040538
Service Center Water
Pump Switch
040532b
Summary of Contents for CAYMAN 2007
Page 12: ...GENERAL INFORMATION 1 CAYMAN 2007 8 NOTES...
Page 14: ......
Page 16: ......
Page 52: ...DRIVING SAFETY 2 CAYMAN 2007 48 NOTES...
Page 80: ...EXTERIOR INTERIOR CARE 3 CAYMAN 2007 76 NOTES...
Page 100: ...APPLIANCES 4 CAYMAN 2007 96 NOTES...
Page 132: ...WATER SYSTEMS 6 CAYMAN 2007 128 NOTES...
Page 160: ...ELECTRICAL SYSTEMS HOUSE 8 156 CAYMAN 2007 NOTES...
Page 226: ...INDEX 222 CAYMAN 2007 NOTES...