Section 7
--- LP-Gas Systems
Cayman 2005
244
Damage to the regulator can occur when the tank is overfilled. The regulator is designed to work
with vapor only. This is why the tank is filled to only 80% of its liquid capacity. The other 20% allows
for vaporization of the liquid. The primary vapor valve is located in the vapor section of the tank. In
an overfilled tank, liquefied petroleum can fill the regulator. As the liquid vaporizes, it can freeze the
diaphragm. High tank pressure on a frozen diaphragm can cause a rupture and result in erratic pressure
regulation. This is why it is important to have the LP-Gas pressure checked for proper pressure and
accurate regulation during appliance operation. Erratic pressure regulation dramatically affects refriger-
ator operation on LP-Gas.
Manometers:
The manometer is the best way to accurately deter-
mine LP-Gas pressure. There are two different styles of
manometers: Gauge and U-tube. Gas pressure is meas-
ured in Inches of Water Column. This is the amount of
pressure applied to one side of a U-shaped tube half filled
with water. The amount of pressure needed to raise the
column of water
11"
represents
11 Inches of Water
Column
.
WARNING:
Do not attempt to adjust
the regulator.
Adjustments require spe-
cial equipment. Failure to
follow these instructions
may result in a fire or
explosion, and can cause
severe personal injury
or death. Do not operate
LP-Gas appliances until
the LP-Gas pressure is
checked and a leak down
test is performed!
050259e
U-Tube Testing Layout
050260
Manometer Gauge
Summary of Contents for Cayman 2005
Page 14: ......
Page 16: ......
Page 28: ......
Page 30: ......
Page 76: ...Section 2 Driving Safety Cayman 2005 76 100179D Weight Label...
Page 81: ...Driving Safety Section 2 Cayman 2005 81 020254 Cargo Carrying Capacity Flowchart...
Page 83: ...Driving Safety Section 2 Cayman 2005 83 020255k Actual Worksheet...
Page 84: ...Section 2 Driving Safety Cayman 2005 84 Weight Record Sheet...
Page 85: ...Driving Safety Section 2 Cayman 2005 85...
Page 86: ...Section 2 Driving Safety Cayman 2005 86 010725 010726c VIEWS Front Rear...
Page 87: ...Driving Safety Section 2 Cayman 2005 87 010723f 010724e Roadside Curbside...
Page 95: ...Driving Safety Section 2 Cayman 2005 95 NOTES...
Page 96: ...Section 2 Driving Safety Cayman 2005 96 NOTES...
Page 98: ......
Page 108: ...Section 3 Exterior Interior Care Cayman 2005 108 Fabric Specifications Charts...
Page 109: ...Exterior Interior Care Section 3 Cayman 2005 109...
Page 134: ...Section 3 Exterior Interior Care Cayman 2005 134 NOTES...
Page 136: ......
Page 165: ...Appliances Section 4 Cayman 2005 165 NOTES...
Page 166: ...Section 4 Appliances Cayman 2005 166 NOTES...
Page 168: ......
Page 203: ...Equipment Section 5 Cayman 2005 203 NOTES...
Page 204: ...Section 5 Equipment Cayman 2005 204 NOTES...
Page 206: ......
Page 229: ...Water Systems Section 6 Cayman 2005 229 WATER SYSTEM DIAGRAM 040487c Typical Layout...
Page 230: ...Section 6 Water Systems Cayman 2005 230 NOTES...
Page 232: ......
Page 250: ...Section 7 LP Gas Systems Cayman 2005 250 NOTES...
Page 252: ......
Page 286: ...Section 8 Electrical Systems House Cayman 2005 286 NOTES...
Page 288: ......
Page 292: ...Section 9 Electrical Systems Chassis Cayman 2005 292 080427f 080387C 080388c...
Page 315: ...Electrical Systems Chassis Section 9 Cayman 2005 315 ENGINE NO START FLOW CHART...
Page 316: ...Section 9 Electrical Systems Chassis Cayman 2005 316 NOTES...
Page 318: ......
Page 376: ...Section 10 Chassis Information Cayman 2005 376 LUBRICATION CHARTS 070166G FRONT...
Page 382: ...Section 10 Chassis Information Cayman 2005 382 METRIC U S CONVERSION CHART...
Page 384: ...Section 10 Chassis Information Cayman 2005 384...
Page 385: ...Chassis Information Section 10 Cayman 2005 385...
Page 386: ...Section 10 Chassis Information Cayman 2005 386...
Page 387: ...Chassis Information Section 10 Cayman 2005 387...
Page 389: ...Cayman 2005 INdex...
Page 390: ......