2.1 Warning to the user

All the local and national regulations, and 

in particular those relating to national and 

European standards, must be observed when 

installing the appliance.
An incorrectly installed heating appliance can 

cause serious accidents

 (chimney fires, burning of 

plastic insulation materials, in partition walls, etc.). 
This stove is exempted by DEFRA for burning wood 

logs in UK Smoke Control Areas (SCA). DEFRA 

exemption is dependent upon the appliance being 

fitted with a mechanical stop to prevent closure of the 

secondary air control beyond the 25% open position. 

You  should  check  that  this  stop  mechanism  is  fitted 

before installation of the stove and certainly before 

using the stove in a SCA to burn wood logs. If the stop 

mechanism  is  fitted  then  the  minimum  chimney  flue 

diameter can be 125 mm but if the stop mechanism 

is  not  fitted  then  the  stove  is  not  exempted  and 

the  minimum  chimney  flue  diameter  is  150  mm  in 

accordance with Approved Document J of the building 

regulations.

The insulation of both the appliance and the 

exhaust gas pipe has to be reinforced

 and done 

according to the Standards and the Building Regulations 

for safety reasons. The installation must be carried 

out according to the Standards and the Building 

Regulations. Failure to respect the manufacturer’s 

instructions will invalidate the warranty.
The manufacturer’s responsibility shall be limited to 

the supply of the appliance.

2.2 Location of the unit

Ventilation :

 For satisfactory appliance operation 

with a 

natural draught

,  check  that  sufficient  air 

for combustion is available in the room. In houses 

equipped with one VMC (controlled mechanical 

ventilation), this one aspire and renew the ambient 

air ; in this case, the residence is under slight low 

pressure and a 

non-sealable

 external air intake must 

be installed in addition to the chimney itself, at least 

50cm² in section.

Position of the unit :

 For new installations, select 

a central position within the house, to provide a 

good heat distribution around the building. The heat 

distribution towards the other rooms will be made 

through the communicating doors. These rooms must 

be  at  low  pressure  or  fitted  with 

non-adjustable 

air registers,

 

placed so that they cannot be 

obstructed

, to encourage circulation of the hot air.

Floor and walls :

 make sure there are not combustible 

or covered with non combustible material. Otherwise 

it must be necessary to install a non combustible 

protection.

2. Installation instructions

Figure 3  - Minimum clearances

Figure 2 - Smoke exit on the top

Summary of Contents for 134 06 05

Page 1: ...scription of the appliance Installation instructions Operating instructions Spare parts Warranty certificate Document n 1303 2 25 10 2012 Technical manual to be saved by the user for future reference...

Page 2: ...d to meet its customers needs FRANCO BELGE which can boast a 80 year experience in the industry of heating devices uses state of the art technologies to design and manufacture its whole range of produ...

Page 3: ...under the grate when using smokeless fuels Reference 134 06 05 Nominal heat output kW 5 9 Chimney draft required Pa 12 Hearth dimensions width mm 429 depth mm 240 height mm 225 Log dimensions lenght...

Page 4: ...ulations for safety reasons The installation must be carried out according to the Standards and the Building Regulations Failure to respect the manufacturer s instructions will invalidate the warranty...

Page 5: ...ss of any non combustible floor under the hearth The hearth must protrude at least 300 mm in front of the stove and 150 mm each side Hearths are provided to prevent combustion appliances setting fire...

Page 6: ...st be clean It should be swept to remove soot and dislodge tar deposits The flue must be well insulated If the flue inner wall surfaces are cold a good thermal draw is impossible causing condensation...

Page 7: ...out the smokes from the exhaust gas pipe The connection pipe and any draught stabiliser must have access for cleaning 2 8 Door closing pressure Figure 7 The closing latch rotates around a pressure scr...

Page 8: ...elling may occur Persistent fume emission is dangerous and must not be tolerated If fume emission does persist Open doors and windows to ventilate room Let the fire go out and dispose of fuel from the...

Page 9: ...with the door 5 10 mm ajar After several minutes the flames from the firebed are diminishing add 2 half sized logs and keep the door ajar and the air controls unaltered About 12 minutes from the Start...

Page 10: ...ppliance must be cleaned regularly together with the connecting pipe and the flue pipe Open the door and remove all deposits in the firebox and clean the removable fire grate Cleaning of the glass doo...

Page 11: ...y burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pressur...

Page 12: ...g plate Y P L E J 2 23 262614 00 Heat shield Y P L E J 1 24 265606 00 Knob Y P L E J 1 25 265608 00 Knob Y P L E J 1 26 270402 00 Air control flap Y P L E J 1 27 270417 00 Air control flap Y P L E J 1...

Page 13: ...05 Technical manual 1303 13 Figure 9 Stove exploded view 37 5 6 40 21 3 3 26 11 1 30 4 8 10 19 43 42 20 2 24 16 16 34 15 22 9 38 39 6 6 27 33 35 18 5 36 29 28 23 25 32 45 2 31 17 13 46 47 48 7 12 13 1...

Page 14: ...331116 77 Main door L 1 43 331116 79 Main door J 1 43 331116 EF Main door Y 1 44 332004 Air duct Y P L E J 1 45 352175 RH Top plate P 1 45 352175 RP Top plate E 1 45 352175 77 Top plate L 1 45 352175...

Page 15: ...Technical manual 1303 15 Notes Monaco 134 06 05...

Page 16: ...costly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two years for all appliances with the exception of closed c...

Reviews: