Monaco 134 06 05 Technical Manual Download Page 1

Monaco

Multi fuel stove

BS EN 13240

Model : 134 06 05

Nominal output : 

5,9 kW (wood)

8,8 kW (solid mineral fuels)

Description of the appliance

Installation instructions

Operating instructions

Spare parts

Warranty certificate

Document n°1303-2

25/10/2012

Technical manual

to be saved

by the user

for future reference

Parc d’activités de la Verte Rue

Allée des Prêles

59270 BAILLEUL

Tél. : 03 28 40 32 50

Subject to modifications

Summary of Contents for 134 06 05

Page 1: ...scription of the appliance Installation instructions Operating instructions Spare parts Warranty certificate Document n 1303 2 25 10 2012 Technical manual to be saved by the user for future reference...

Page 2: ...d to meet its customers needs FRANCO BELGE which can boast a 80 year experience in the industry of heating devices uses state of the art technologies to design and manufacture its whole range of produ...

Page 3: ...under the grate when using smokeless fuels Reference 134 06 05 Nominal heat output kW 5 9 Chimney draft required Pa 12 Hearth dimensions width mm 429 depth mm 240 height mm 225 Log dimensions lenght...

Page 4: ...ulations for safety reasons The installation must be carried out according to the Standards and the Building Regulations Failure to respect the manufacturer s instructions will invalidate the warranty...

Page 5: ...ss of any non combustible floor under the hearth The hearth must protrude at least 300 mm in front of the stove and 150 mm each side Hearths are provided to prevent combustion appliances setting fire...

Page 6: ...st be clean It should be swept to remove soot and dislodge tar deposits The flue must be well insulated If the flue inner wall surfaces are cold a good thermal draw is impossible causing condensation...

Page 7: ...out the smokes from the exhaust gas pipe The connection pipe and any draught stabiliser must have access for cleaning 2 8 Door closing pressure Figure 7 The closing latch rotates around a pressure scr...

Page 8: ...elling may occur Persistent fume emission is dangerous and must not be tolerated If fume emission does persist Open doors and windows to ventilate room Let the fire go out and dispose of fuel from the...

Page 9: ...with the door 5 10 mm ajar After several minutes the flames from the firebed are diminishing add 2 half sized logs and keep the door ajar and the air controls unaltered About 12 minutes from the Start...

Page 10: ...ppliance must be cleaned regularly together with the connecting pipe and the flue pipe Open the door and remove all deposits in the firebox and clean the removable fire grate Cleaning of the glass doo...

Page 11: ...y burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pressur...

Page 12: ...g plate Y P L E J 2 23 262614 00 Heat shield Y P L E J 1 24 265606 00 Knob Y P L E J 1 25 265608 00 Knob Y P L E J 1 26 270402 00 Air control flap Y P L E J 1 27 270417 00 Air control flap Y P L E J 1...

Page 13: ...05 Technical manual 1303 13 Figure 9 Stove exploded view 37 5 6 40 21 3 3 26 11 1 30 4 8 10 19 43 42 20 2 24 16 16 34 15 22 9 38 39 6 6 27 33 35 18 5 36 29 28 23 25 32 45 2 31 17 13 46 47 48 7 12 13 1...

Page 14: ...331116 77 Main door L 1 43 331116 79 Main door J 1 43 331116 EF Main door Y 1 44 332004 Air duct Y P L E J 1 45 352175 RH Top plate P 1 45 352175 RP Top plate E 1 45 352175 77 Top plate L 1 45 352175...

Page 15: ...Technical manual 1303 15 Notes Monaco 134 06 05...

Page 16: ...costly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two years for all appliances with the exception of closed c...

Reviews: