Tool Kit for 250 Slip-in Receptacle Terminals
Doc No: ATS-6382721HM Release Date: 12-13-13
UNCONTROLLED COPY
Page 3 of 8
Revision: A
Revision Date: 12-13-13
SWING OPEN
TERMINAL
PUSH HERE TO
OPEN WIRE STOP
LOCATOR
TERMINAL
IN PLACE
Figure 4
LOCATOR LATCH
IN OPEN POSITION
ANVILS
POWER
CRIMP
HEAD
Figure 1
PUNCHES
M4 X 10 LONG
BHCS
M4 X 18 LONG
BHCS
SWING
LOCATOR
OPEN
PRESS DOWN
ON THE BRASS
PIVOT SHAFT
LIFT UP ON
THE LOCATOR
Figure 2
Locator Installation and Removal
Follow the steps below to install or replace the locator. See Figure 2.
To install the locator
1.
Position the locator with the hole over the brass pivot shaft and snap it
into place.
To remove the locator
1.
Open the crimp hand tool.
2.
Swing the existing locator open and away from the hand
tool.
3.
Firmly press down on the brass pivot shaft with your
thumb, while pulling the locator up. Slip the locator off the
top of the brass pivot shaft.
OPERATION
Open the tool by squeezing the
handles together, at the end of the
closing stroke, the ratchet
mechanism will release the handles,
and the hand tool will spring open.
Crimping Terminals
1.
Select the desired terminal
listed in the preceding charts.
2.
Turn the Locator Lock Latch down to unlock. See Figure 3.
3.
Swing the terminal locator away from the crimp tool shown in Figure 4. Some terminals with large insulation
grips may interfere with the crimp tooling when swinging the locator into position. The terminal must then be
loaded into the locator in the closed/crimp position. See Figure 5.
4.
Press down on the wire stop on the locator as shown in Figure1. Insert the proper terminal into the proper
nest opening. Make sure when choosing the nest opening, it will correspond with the A, B or C profile on the
hand tool.
Figure 3
LATCH LOCKED