AT-200 Air-Powered Crimp Tool
Doc No: TM-192790001
Release Date: 07-01-02
UNCONTROLLED COPY
Page 6 of 18
Revision: D
Revision Date:11-10-09
SAFETY
(UNLOCKED)
SAFETY
(LOCKED)
TRIGGER
TRIGGER
PULL OUT
PUSH IN
Figure 3
3.
Lock the trigger by engaging the red aluminum safety. Pull the safety outward from the end of the trigger and
rotate it until the next detent position engages. See Figure 3.
Note
: Always use the safety or disconnect air supply when changing crimping heads.
4.
For the proper crimping head, use the order number located on the label of the terminal/connector container.
5.
Strip the proper wire to the minimum length located on the label of terminal/connector container or on the air
powered crimp tool head specification sheet.