Table 8-1 Alarm Messages
Category
Fault Text
Cause
Notes
Alarm
Unknown motor
connected. May
not achieve rated
speed
Connected motor is not
known to the controller.
Be aware that
maximum allowed
velocity may not be
achievable.
Alarm
Extensive deviation
The difference between
actual and set positions
is outside of allowed
bounds.
Inspect system for
blockages.
Lower maximum
allowable
accelerations.
Increase maximum
torque.
Warning
Negative position
limit exceeded
Move the plate to
valid range using
Jog +
Warning
Positive position
limit exceeded
Move the plate to
valid range using
Jog -
Warning
Target position out
of travel range
Profile target is outside
the travel range.
Modify the profile
Warning
Drive warning
Investigate warning
message code in
Drive Info.
IMPORTANT
If in doubt about an error message, please contact a Mold-Masters
representative.
8-3
TROUBLESHOOTING
E-Drive Controller User Manual
© 2021 Mold-Masters (2007) Limited. All Rights Reserved.