Device Description
Touch-Panels for Industrial Automation
DVI-Panel
Commissioning
© 2005 by Moeller GmbH
02/05 AWB2720-1524GB
15
5.4
DVI-I
NTERFACE
The DVI Interface is used to connect the DVI-Panel with a XCC-601 or with
a DVI-Interface of a standard PC. For that a standard DVI cable should be
used (see accessories).
The Video Interface is compatible to the Single Link DVI-D Standard. For
practical reasons a DVI-I connector is used, where the analog inputs pins
have no function (not connected).
Pin-Nr
Signal
Description
1
RX2-
TMDS Data 2- Input
2
RX2+
TMDS Data 2+ Input
3
RX2/RX4 shield TMDS Shield for Data 2 & 4
4
RX4-
Internally not connected
5
RX4+
Internally not connected
6
DDC Clock
Digital Data Channel Clock Input
7
DDC Data
Digital Data Channel Data I/O
8
Analog Vsync
Internally not connected
9
RX1-
TMDS Data 1- Input
10
RX1+
TMDS Data 1+
Input
11
RX1/RX3 shield TMDS Shield for Data 1 & 3
12
RX3-
Internally not connected
13
RX3+
Internally not connected
14
+5 V
+5V for DDC
15 TTL
Ground
16
HPD
Hot Plug Detect
17
RX0-
TMDS Receive 0-
18
RX0+
TMDS Receive 0+
19
RX0/RX5 shield TMDS Shield for Data 0 & 5
20
RX5-
Internally not connected
21
RX5+
Internally not connected
22
Clock shield
TMDS Shield for Clock
23
Clock+
TMDS Clock+ Input
24
Clock-
TMDS Clock- Input
C1
Analog Red
Internally not connected
C2
Analog Green
Internally not connected
C3
Analog Blue
Internally not connected
C4
Analog Hsync
Internally not connected
C5
Analog Ground Internally not connected
To ensure disturbance-free operation, it is strongly
recommended to use the Touch/PowerSupply cables
from the original accessories. (see accessories)
5.5 R
OTARY SWITCH
To compensate the length of the DVI cable, the DVI-Panel is equiped with a
rotary switch.
Normaly the default setting (position '0') is o.k. and the picture on the DVI-
Panel is stable. If you encounter flickering pixels with short cables, please
switch to a different position towards 'F'
0 is for long cables
F is for short cables
Default is 0
1 8
C1, C2
17 24
C3, C4
5