background image

75-511.13

 

  Qty.  Part Number 

-1 

-2 

-3 

-4 

-5 

-6 

-7 

-8 

-9 

-10 

-11

 Regulator Kit for 

 

 Honeywell VR8204, VR8200A, 

5H71926A2  X  X  X X  X X X X X X X 

 VR8300A

  

 Regulator Kit for Honeywell 

 

 

V800A

 

5H7057A2               

X

 Regulator Kit for Robertshaw  

 

 

7200IPER, 7200ER 

5H73135A2  X  X  X X  X X

 Regulator Kit for Robertshaw  

  

 

700BDER, 700DERHC, 

5H73134A2          X X 

X

 

7000BER, 7000ERHC

  

 

Regulator Kit for White Rodgers 

  

 36E36, 36C38, 36C03

 

Main Burner Orifice 

) 5H54751B  37  45  42 45  43 40 37 42 37 43 42

 Drill Size 

 

Qty 

(1)  (2)  (2) (3)  (3) (3) (3) (4) (4) (6) (6)

  Carton Label 

5H78020B  1  2  3 4  5 6 7 8 9 10 

11

 

 

 

Description 

Qty. 

Part Number

 

Robertshaw Pilot Orifice 

5H71962A2

  Parts Common To Kit

Air Shutter 

Same As Main Burner Orifice Qty. 

3H20634A2

  (Table 5.3)

 

Gas Designation Disc 

5H604841A

 

Conversion Kit Rating Plate 

5H73734A

 

Instruction Sheet 

5H72298A 

 Qty. 

Part Number -1  -2 -3 -4 -5 -6 -7  -8 -9 -10 -11 -12 -13 -14 -15 -16 -17 -18

 Regulator Kit for

 

 

Honeywell VR8200

 

1  393691           X   X  X    X X X X X X 

 

VR8300, VR8204, VR8304

 Regulator Kit for Honeywell 

 

 

V800, VR800, VR8440

 

1  391937  X  X X X X X X  X X X  X  X  X  X  X  X

 

Regulator Kit for Robertshaw 

 

 

7200ER, 7200IPER 

1  78776            X 

X X X X

 Regulator Kit for Robertshaw

 

 7000BER/BDER/ERHC/DERHC 

85478 

X  X X X X X X  X

 Regulator Kit for 

 

 

Robertshaw 7222IPER 

 

54302 

X  X    X X X X  X X X  X  X  X  X        X

 Main Burner Orifice  

)  5H54751B… 52  45 49 45 42 45 43  40 43 42  43  39  40  37  45  48  37  43 

 

Drill Size

 

 

Qty. 

(1)  (1) (2) (2) (2) (3) (3)  (3) (4) (4)  (5)  (5)  (6)  (1)  (2)  (3)  (3)  (6)

 Carton Label

 

1 5H73133C… 1  2 3 4 5 6 7  8 9 10 11 12 13 14 15 16 17 18

 

Description 

Qty. 

Part Number

 

Honeywell Pilot Orifice 

Orifice Stamp BBR-11

  Parts Common To Kits

Robertshaw Pilot Orifice 

Orifice Stamp 10 LP

  (Table 5.1 and Table 5.2)

 

PSE Pilot Orifice 

Orifice Stamp 012 LP

 

Air Shutter 

Same As Main Burner Orifice Qty. 

3H20634A2

 

Gas Designation Disc 

5H604841A

 

Conversion Kit Rating Plate 

5H73734A

 

Instruction Sheet 

5H72298A 

5

Table 5.2 – Conversion Kit Parts List, Natural to Propane for Base Kit 3H033749-xxxx (Refer to Table 2.2)

Table 5.3 – Conversion Kit Parts List, Natural to Propane for Base Kit 3H036483-xxxx (Refer to Table 2.3)

 

 

Qty 

Part 

Number -1  -2 -3 -4 -5 -6  -7  -8  -9 -10  -11 -12

 

Regulator 

Kit 

for 

 

 

 

                 

  Honeywell VR8200,

 

1  393691    x x x x x  x  x  x  x  x  x

 

VR8300, 

VR8204, 

VR8304 

 

 

                 

  Regulator Kit for Honeywell  

 

 

 

 

 

 

 

 

 

 

 

 

 

  V800, VR800, VR8440

 

1 391937                  x x

  Regulator Kit for Robertshaw 

  

 

                 

  7200ER, 7200IPER

 

1  78776  x  x x x x x  x  x     

 

 Regulator Kit for Robertshaw    

 

                 

 7000BER/BDER/ERHC/DERHC

 

1  85478              x x  x x

 

Regulator 

Kit 

for 

 

 

                 

  Robertshaw 7222IPER

 

1  54302  x  x x x x           

 

Regulator 

Kit 

for 

 

 

                 

  White-Rogers 36E, 36C

 

1  92-0659  x  x x x x x  x  x  x  x  x  x

  Main Burner Orifice

 

)  5H54751  52  45 39 45 43 39  43  42  36  39  41  42

  Drill Size

 

 

Qty 

(1)  (1) (1) (2) (2) (2)  (3)  (3)  (3)  (4)  (5)  (6)

Table 5.1 – Conversion Kit Parts List, Natural to Propane for Base Kit 3H034670-xxxx (Refer to Table 2.1)

{

 

  

5H73134A2  X  X  X X  X X X X X X X 

 

{

INSTALLATION

Summary of Contents for PD/BD

Page 1: ... model number are N1 or S1 This is item 2 in Figure 2 1 Any other number code disqualifies the unit for conversion 3 Item 3 in Figure 2 1 in the serial number box designates the date the unit was built In Figure 2 1 the numbers 3601 are shown This number is interpreted as the thirty sixth week of 2001 Prior to January 1995 the digits preceding the year represent month of manufacture After January ...

Page 2: ...NFG DFP IFP DFS IFS 75 100 125 150 175 200 225 250 300 350 400 Suffix 1 2 3 4 5 6 7 8 9 10 11 Figure 2 1 Typical Serial Plate Modine Manufacturing Company 1221 Magnolia Ave Buena Vista VA 24416 Phone 540 261 2166 PD 250AA0111 115 5 7 1 60 30011013601 0978 6 0 I ANS Z83 8 96 Natural 3 5 CGA 2 6 M96 0 0 MEA 293 96 E j l k Model Type Model Size PD BD PDP BDP 30 50 75 100 125 150 175 200 250 300 350 4...

Page 3: ... After removing burner assembly proceed with step 4 page 4 For Indoor Duct Furnace Models On DHE IHE models lower the controls enclosure cover and disconnect the pilot gas supply line and thermocouple at the gas valve On models DJE IJE DFG IFG NFG DFP IFP DBG IBG DCG ICG DBP IBP and DCP ICP models the gas controls are exposed On models DFS IFS remove lower assess door to expose gas controls and bu...

Page 4: ...the pilot orifice stamped BCR 18 with the pilot orifice supplied in the conversion kit stamped BBR 11 or 12 For PSE pilots replace the pilot orifice stamped 018N with the pilot orifice supplied in the conversion kit stamped 012LP 5 Verify that pilot is oriented to main burner as shown in Fig 4 3 6 Exchange main burner orifice s and install air shutters see Figure 4 4 Check the orifice number stamp...

Page 5: ...4751B 52 45 49 45 42 45 43 40 43 42 43 39 40 37 45 48 37 43 Drill Size Qty 1 1 2 2 2 3 3 3 4 4 5 5 6 1 2 3 3 6 Carton Label 1 5H73133C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Description Qty Part Number Honeywell Pilot Orifice 1 Orifice Stamp BBR 11 Parts Common To Kits Robertshaw Pilot Orifice 1 Orifice Stamp 10 LP Table 5 1 and Table 5 2 PSE Pilot Orifice 1 Orifice Stamp 012 LP Air Shutter ...

Page 6: ... outlet pressure should be 10 in w c The outlet pressure can be adjusted at the combination gas control s regulator Turning the adjustment clockwise will increase the outlet pressure while turning it counterclockwise will decrease the pressure 18 Verify normal operating sequence of ignition system according to the Installation Service Manual 19 Check for leaks at all joints and connections in the ...

Page 7: ...or the unit heater s rated input The input can be verified at any time simply by checking for the correct main burner orifice size and manifold pressure This information is presented on the conversion kit rating plate EQUIPPED FOR USE WITH PROPANE GAS NTRL 5H604841A INSTALLATION ...

Page 8: ...HVAC Products Modine Manufacturing Company 1500 DeKoven Avenue Racine Wisconsin 53403 2552 I O Model Series Phone 1 866 823 1631 Toll Free All Other Model Series Phone 1 800 828 4328 HEAT Modine Manufacturing Company 2016 ...

Reviews: