CLEANING AND MAINTENANCE INSTRUCTIONS 

There is very little maintenance involved with your electric fireplace. Please follow the few points be-
low: 
 

 

On a semi-annual basis unplug the machine from it’s power source, wait for the heating element 
to cool and dust the fire unit with a dry cloth. Be careful not to brush any wires that may be ex-
posed as you do this. 

 

To clean the glass face of the fireplace simply use your desired glass cleaner with paper towels. 

 

To clean the air inlets/outlets, wipe with a soft cloth or the nozzle of a vacuum cleaner 

 

Dust can easily build up around the heater area under the appliance. Take particular care to 
clean this area on a regular basis to prevent buildup. 

 

If long time no use, please unplug the fireplace and stock it at indoor dry position. 

WIRING DIAGRAM 

MAINTENANCE 

MAINTENANCE 

Touch Control

High
Heater

Low
Heater

Pilot

Po
wer

PCB

FAN
Motor

Heater

Sync
Motor

Relay PCB

Thermal
Cut-Off/
Fuse

AC L

AC N

1 2 3 COM

AC N

AC L

750W

750W

Motor

Touch

12V1 

IN1

ON/OFF

Heater
Control

Light
Control

J13

NTC

AC L

Motor

FAN

FAN

AC L

AC L

AC L

AC L

AC L

Heater

AC IN1

AC IN2

750W

750W

FAN

FAN

Motor

Motor

12V1 

IN1

12V1 

IN2

12V1 OUT1

12V1 OUT2

12V2 OUT1

12V2 OUT2

J13 IR

5V TX GND TR

12V -

Flame Light

Coal

 Li

ght

Hal
o Li
ght

IR

 S

e

nso

r

NTC

Temperature
show

Temperature

Up

Temperature

Down

Summary of Contents for AL45CLX

Page 1: ...Ambiance CLX Electric Series AL45CLX AL60CLX AL80CLX AL100CLX AL144CLX INSTALLATION SERVICE INSTRUCTIONS FOR USE IN UNITED STATES AND CANDA ...

Page 2: ...ctric heaters have hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are or are stored This fireplace meets the construction and safety standards of H U D for application in manufactured homes when installed according to these instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference ...

Page 3: ...t in any manner 9 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable vapors or liquids are used or stored 10 Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 11 This heater includes a visual alarm to warn that parts of the heater are gettin...

Page 4: ...ipped over 15 Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire However if you have to use an extension cord the cord shall be No 12 AWG minimum size and rated not less than 1875 watts 16 SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS POWER DATA AL 100 CLX AL 60CLX AL 45 CLX AL 80 CLX AL 144 CLX Volts HZ Amps AC 120V 60Hz 15 Amps AC 120V 60Hz 15 Am...

Page 5: ...ace Dimensions Firebox Dimensions AL45CLX 27 W x 10 H 45 W x 25 1 2 H 29 1 4 W x 19 1 4 H x 5 1 2 D AL60CLX 42 W x 10 H 60 W x 25 1 2 H 44 1 4 W x 19 1 4 H x 5 1 2 D AL80CLX 62 W x 10 H 80 W x 25 1 2 H 64 1 4 W x 19 1 4 H x 5 1 2 D AL100CLX 82 W x 10 H 100 W x 25 1 2 H 84 1 4 W x 19 1 4 H x 5 1 2 D AL144CLX 126 W x 10 H 144 W x 25 1 2 H 130 3 4 W x 19 1 4 H x 5 1 2 D Glacier Crystal Resin Coal ...

Page 6: ...d protected 120 volt outlet Always use ground fault protection where re quired by the electrical code Never use an extension cord with this product WARNING Do not operate the unit if it is damaged or has malfunctioned If you suspect the unit is damaged return the unit to an authorized service facility for examination electrical or mechanical ad justment or repair LOCATING FIREPLACE CAUTION Do not ...

Page 7: ...To reduce the risk of fire do not store or use gasoline or other flammable vapors in the vicinity of this or any other heater Installing fireplace Select a suitable location that is not suscep tible to moisture and is a safe distance from drapes furniture and high traffic areas A qualified electrician should add an electrical outlet per local building codes See shaded area on recessed installation...

Page 8: ...ast 4 of the screws are driven in to a solid backing AL45CLX 30 W x 19 3 4 H x 4 D AL60CLX 45 W x 19 3 4 H x 4 D AL80CLX 65 W x 19 3 4 H x 4 D AL100CLX 85 W x 19 3 4 H x 4 D AL144CLX 131 1 2 W x 19 3 4 H x 4 D 2 Attach L metal brackets to the fire unit with he provided small washer head screws Fireplace will stand proud of the finished wall opening by 1 1 8 inches this area must not be blocked by ...

Page 9: ...ounting bracket by slotting the key hole slots on the fire unit over the hooks on the mounting bracket 4 Use the included L metal bracket to secure the bottom of the fire unit to the wall This is a semi permanent installation Remove screws to relocate AL45CLX 27 3 4 inches AL60CLX 29 3 4 inches AL80CLX 49 3 4 inches AL100CLX 69 inches AL144CLX 113 inches Use the chart below to see proper distance ...

Page 10: ...hen the switch turns on this orange pilot lamp is always on It shows the fire is ener gized The status light above shows that the power is on and the heater is on low The status light above shows that the power is on and the heater is on high Heater Backlight To use the built in digital thermostat start by set ting the heat to high or low You may now set the temperature limit by using the up or do...

Page 11: ...left button will bring you to the home screen Pressing Enter while this icon is highlighted will bring you to the Temperature control menu Pressing up will turn the heater to high heat Pressing down will turn the heater to low heat long press down to turn the heater off Pressing right will enable the thermostat sub menu Use the up and down buttons to select the set temperature displayed on the fac...

Page 12: ...E TOUCH CONTROL MFRR1 REMOTE CONTROL IR RECEIVER MF12VT1 TRANSFORMER MFHF12015 HEATER FAN 120 V 1500 WATTS MFPHF AL HEATER 120 V 1500 WATTS MFSM120 SPINDLE MOTOR 120 V 50 60 HZ MFP45 LED LED LIGHT STRIP AL 45 MFP60 LED LED LIGHT STRIP AL 60 MFP80 LED LED LIGHT STRIP AL 80 MFP100 LED LED LIGHT STRIP AL 100 MFP144 LED LED LIGHT STRIP AL 144 MF PS1 POWER SWITCH MFR1 REMOTE CONTROL ...

Page 13: ...Q My touch screen will not operate properly A The fireplace must be installed to a plumb vertical wall for correct operation of touch controls Re move power source for 30 seconds to allow unit to reset Attach glass face turn on power and wait for indicator lights to turn off Q Low long will the LED lights last A LED Lamps have a life span of up to 20 years Q Can the sensitivity of the touch screen...

Page 14: ...or any standard grease to contacts with rod and metal B Motor is defective B Replace motor A Wiring is loose A Disconnect unit from power source and inspect for loose connections Heater does not provide heat when on B Thermal snap disc has been tripped B Turn unit off and unplug unit for 5 minutes Plug back in and turn unit on If plug cannot be reached reset breaker and turn unit back on C Heater ...

Page 15: ...cia is seated correctly on pins B Fireplace was installed with the power in on position B Turn main power switch to the off position for 30 seconds Switch the fireplace back into the on position for 20 seconds for complete reboot of touch control C Not operating touch control properly with finger C Press flat part of finger firmly on the touch screen and apply moderate pressure D Loose connection ...

Page 16: ...Dust can easily build up around the heater area under the appliance Take particular care to clean this area on a regular basis to prevent buildup If long time no use please unplug the fireplace and stock it at indoor dry position WIRING DIAGRAM MAINTENANCE Touch Control High Heater Low Heater Pilot Power PCB FAN Motor Heater Sync Motor Relay PCB Thermal Cut Off Fuse AC L AC N 1 2 3 COM AC N AC L 7...

Page 17: ...17 MAINTENANCE NOTES ...

Page 18: ...18 NOTES MAINTENANCE ...

Page 19: ...19 MAINTENANCE NOTES ...

Page 20: ...20 2015 www modernflames com Please dispose of properly ...

Reviews: