31
The refrigerant used in the machine is R404a fluid. Below find the components of the fluid: PENTAFLUOROETANE
(HFC R125)44%
ETHANE 1, 1, 1-TRIFLUORO (HFC R143A)52%
ETHANE 1, 1, 1, 2 TERAFLUORO (HFC R134A)4%
IDENTIFICATION OF DANGERS
The rapid evaporation of the liquid can cause freezing. The inhalation of high concentrations of vapour can cause
irregular heartbeat, short term narcotic effects (including vertigo , headache and mental confusion), fainting and
death.
Effects to the eyes: Freezing or cold burns caused by contact with the liquid.
Effects on the skin: Freezing or cold burns caused by contact with the liquid.
Effects of ingestion. Ingestion is not considered a means of exposure.
FIRST AID
Eyes:
In the case of contact, wash the eye well using a large amount of water for at least 15 minutes. Consult a
doctor.
Effects on the skin:
Wash with water for at least 15 minutes after excessive contact. If necessary, cure freezing by
gently warming the area in question. Consult a doctor in the case of irritation.
Ingestion:
Ingestion is not considered a means if exposure.
Inhalation: If large concentrations are inhaled, go into the open air, Keep the person calm. If the person
cannot breath, perform artificial respiration. If respiration is difficult, apply oxygen. Consult a doctor.
BZ 1014
BZ 1010
Blast Chiller & Freezer
Blast Chiller & Freezer
Ventilated cooling system
Ventilated cooling system
Automatic Defrost (No Frost)
Automatic Defrost (No Frost)
Interior structure in Stainless steel 304
Interior structure in Stainless steel 304
Exterior structure in Stainless steel 304
Exterior structure in Stainless steel 304
1 Door
1 Door
14 pairs Pan Support GN1/1 or 400x600
(Pans/Trays are not included)
10 pairs Pan Support GN1/1 or 400x600
(Pans/Trays are not included)
Electronic thermostat
Electronic thermostat
Digital LED temperature display
Digital LED temperature display
Self-closing door
Self-closing door
Capacity : 494 liters
Capacity : 368 liters
Voltage / Frequency : 230 V / 50 Hz
Voltage / Frequency : 230 V / 50 Hz
Blast chiller : +70°C to +3°C in 90 minutes
Blast chiller : +70°C to +3°C in 90 minutes
Shock Freezer : +70°C to -18°C in 240 minutes
Shock Freezer : +70°C to -18°C in 240 minutes
BZ 1005
Blast Chiller & Freezer
Ventilated cooling system
Automatic Defrost (No Frost)
Interior structure in Stainless steel 304
Exterior structure in Stainless steel 304
Part 8: Refrigerant Technical Card
Part 7: Specification
Summary of Contents for BZ 1005