2.2 Before Mounting
This section of the manual provides an overview of the variety of S14 connection options,
the preparatory steps and the tools required for mounting.
2.2.1 Overview Of Cable Connections
The following cables can be used with the S14 (see also
Section 1.10, «Available Accessories»):
•
MOBOTIX patch cable
: This supplied MOBOTIX cable is designed for direct con-
nection to the
MX-Patch-Box
, the
MX-NPA-Box
or a standard network port (only
in indoor areas).
•
Ethernet installation cable
: As an alternative to the
MOBOTIX patch cable
(see above)
an Ethernet installation cable can also be fitted directly onto the integrated LSA
cutting clamp.
•
MOBOTIX USB cable with MiniUSB connector
: This MOBOTIX cable provides the
required impermeability, even in adverse weather conditions, and thereby prevents
corrosion of the connectors, for example, on an external USB hard drive.
•
Sensor cable for the sensor modules (S14D only)
: The sensor modules are con-
nected to the S14D via this cable. A separate cable is required for each sensor
module (max. 2 m/6.6 ft).
•
Additional cable for MxBus connections, microphone and speaker
: Additional
MOBOTIX modules can be connected via this multi-wire cable. The other camera
opening is used for this cable or for single wires, depending on which connection is
used for network cabling (patch or installation cable).
Cam1 Cam2
(S14D only)
MiniUSB
Additional cables or
network installation cables
MOBOTIX patch cables