The charging logic gives priority to the primary battery but meanwhile the secondary is
monitored and recharged in case of need
•
The primary battery is recharged using the parameters related to the temperature of the
containment compartment. It is possible to force a priority charging of the secondary
battery
•
If the display is not touched for 3 minutes, it switches off automatically while keeping the
set functions unaltered. To turn it on again simply touch the screen
•
If manual mode, after 30 minutes of inactivity the system automatically goes into stand-by
mode to reduce electrical consumption. When switched on again, it may take a few
seconds to restore communication with all components
•
The generator switches off automatically 3 minutes after the ignition of the vehicle engine.
Within the first 3 minutes there is the possibility to force the generator working status
confirming the popup message on the display
•
Use only batteries of type PB / AGM / GEL and LiFeP04, selecting the correct charging
algorithm from the control unit.
•
Recommended capacity: from 70 to 400Ah. Do not use old batteries in any
circumstances, as they could cause the Zeus150 generator not to work correctly
•
In any moment is possible to check the status and characteristics of the batteries
•
It is always possible to check the operating status of the system and all its components
•
Do not wash the generator using a pressure washer
•
The generator is not designed to work submerged in water or other liquids; in the event of
flooding, the warranty becomes void and it is necessary to go to an authorized installer.
•
The generator manufacturer is not responsible for battery status or incorrect selection of
the type of batteries to be recharged
1.3 Fuel quality
Zeus150 generator works without problems with the diesel fuel normally available on the market
used for the vehicle’s engine. Addition max. of biodiesel available on the market according to
DIN EN 590. In the winter months diesel fuel is adapted at low temperatures from 0°C to -20°C.
In this way problems can arise only in the case of extremely low external temperatures - as well
as in the vehicle engine - see the instructions of the vehicle manufacturer. In special cases and
at external temperatures above 0°C the Zeus150 generator can also work with heating oil sec.
DIN 51603 (from an additional tank).
If the Zeus150 generator is powered from a separate tank, follow these steps:
•
external temperatures higher than 0°C: use diesel oil sec. DIN EN 590 or heating oil sec.
DIN 51603;
•
external temperatures from 0°C to -20°C: use winter diesel sec. DIN EN 590;
•
outside temperatures from -20°C to -40°C, use arctic gas oil or polar gas oil.
The addition of used oil is not allowed. After using winter diesel or diesel fuel for low
temperatures, fill the fuel lines and the standard diesel fuel pump by running the generator for 15
minutes. The Zeus150 generators are not approved to work with bio-diesel according to DIN EN
14214.