background image

Zeus150 

                                                           User Manual 

V 1.1.5 - 21/10/2020 

          Page 11 of 16 

2.2.3  Language Menu 

The following figure shows the menu related to the different languages for which the system can 
be configured. 

 
 
 
 
 
 
 
 
 
 
 

2.2.4  Service Menu  

 

 

 
 
 
 
 
 
 
 
 
 
 
 

In the above menu it is possible to activate the Service menus related to: 

  Generator 

  Control Unit (reserved for installers) 

  Software update

 

 
The  two  icons  at  the  bottom  right  display  the  status  of  communications  between  the  different 
components of the system: 

-  C 

 communication between the display unit and the power unit 

-  G 

 communication between the power unit and the generator 

 

Both of them have the same visualization mode: 

-  Flashing blue 

 communication OK 

-  Red 

 communication error 

 
 
 
 

Generator 
Menu 

 

Software 
Update 

 

Back to Settings Menu 

 

Control Unit 
Menu 

 

Communication 
between display 
and power unit

 

Communication 
between power 
unit and 
generator

 

Summary of Contents for ZEUS150

Page 1: ...or USER MANUAL ZEUS150 CD Power Supply Diesel IMPORTANT You can obtain the 3 three year warranty extension by registering the product for free on shop mobiltech it More information can be found in cha...

Page 2: ...have a system capable of charging the batteries of your vehicle regardless of the availability of external electricity or weather conditions Installation and commissioning must be performed by specia...

Page 3: ...TENTION NEVER disconnect for any reason the primary battery when the generator is working The operation is very harmful because the cooling of the device will be lost causing possible breakages due to...

Page 4: ...s components Do not wash the generator using a pressure washer The generator is not designed to work submerged in water or other liquids in the event of flooding the warranty becomes void and it is ne...

Page 5: ...w the menu structure is shown HOME SETTINGS TIMER MODE LANGUAGE SERVICE GENERATOR CONTROL UNIT Timer 1 Timer 2 Clock Automatic Manual Battery automatic selection Engine battery forcing Italian English...

Page 6: ...t is therefore recommended to select the desired mode within the first 5 minutes after switching on on The operating mode icon can have the following forms o Automatic mode the icon flashes when the g...

Page 7: ...ntly both graphically and numerically 2 1 2 Thermoelectric generator management Pressing the generator icon the screen display the Menu related to the energy supplied by the thermoelectric generator T...

Page 8: ...menu is shown The battery data is displayed on the left Type Actual voltage The percentage of engine battery charge is displayed on the right side of the screen Battery data Percentage of charge Perc...

Page 9: ...wo available Timers as well as the internal clock To set a timer press the related time and make the desired adjustments in the central part of the screen When the two timers are activated the related...

Page 10: ...e primary battery services with respect to the engine battery Nevertheless the latter is constantly monitored and if its voltage falls below a minimum value it will be immediately charged Battery Engi...

Page 11: ...ers Software update The two icons at the bottom right display the status of communications between the different components of the system C communication between the display unit and the power unit G...

Page 12: ...tatus of the generator components The icons shown in this figure can have on three different colors Blue working element actually active Gray working element actually not active Red failed element err...

Page 13: ...splay shows Service batt low Low voltage of service battery Power on the generator Display shows Service batt overtempt Service battery temperature too high Place the service battery in a more ventila...

Page 14: ...erification Display shows Water overtemperature Coolant temperature too high Wait for the coolant temperature to drop Display shows Water outlet probe error Fault or lack of connection with outlet wat...

Page 15: ...ion R10 rev 5 A1 EN61000 6 1 2007 EN61000 6 3 2007 A1 2011 Standard ENV Cold A EN60068 2 1 15oC Standard acoustic tests EN ISO 3744 Power supplied 150 Wh typical see graphic below Note how the product...

Page 16: ...ch it Mail info mobiltech it service mobiltech it Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of oper...