4 Technical data
Power Supply 12V model Z150CD12
24V model Z150CD24
Operating temperature
-20°C / +40°C
Dimensions and weight
Generator: 550x330x265 mm. 28,9 Kg
Cooling system: 526x175x260 mm. 5,9 Kg
Battery types
Free acid, Pb Seal, LiFePO4
Fuel consumption
From 0,2 to 0,6 lt/h
Electrical consumption
Max (45 sec during power on): up to 15A
Standby: with display on: 190mA
with display off: 120mA
30 minutes after display switch off: 85mA
Max operating height
3000 mt above sea level
Standard EMC
ECE Regulation R10 rev. 5 + A1
EN61000-6-1:2007 + EN61000-6-3:2007+A1:2011
Standard ENV (Cold A)
EN60068-2-1 (-15
o
C)
Standard acoustic tests
EN ISO 3744
Power supplied
150 Wh typical, see graphic below.
Note how the production of energy (horizontal
axis)
varies
according
to
the
external
temperature (vertical axis). In addition, the
system can be affected by other factors such
as humidity, rarefaction of air due to altitude or
atmospheric pressure and positioning of the
cooling radiator.
P.S.:
data subject to change without notice and without changing functionality
5 Warranty
The Zeus150 generator is covered by a two-year warranty, which can be extended to 3 (three)
years by registering the product on
Warranty conditions are available on