Draft
26
DOC-0132 Crewsafe User Manual v.1.2
Mobilarm Ltd. © 2009
·
Way point data is sent from the Display Console to a compatible chart
plotter.
·
If you have the Crewsafe Management System connected to your system
then this system will show an alert state.
CAUTION:
If a crew member moves out of range while carrying a tag then
connection to the network will be broken and Crewsafe will raise a man
overboard alarm. This will cause the same sequence of events to occur
within the Crewsafe system as for a man overboard event (See
for information on canceling alarms).
Network Mute/Acknowledgement of a Man Overboard Alarm
Press the ALARM button on the Display Console. This mute the man overboard
alarm across the Crewsafe network .
Once muted:
·
The audio alarm is reduced to a single beep every 5 seconds on the Display
Console and Internal Routers.
·
Active Tags continue to vibrate.
·
The STROBE light on all routers and Tags will stop flashing, so that night
vision is not affected.
Note:
If a new man overboard, duress, general or manual network alarm is activated
after an earlier alarm has been muted, the system will restart loud repetitive tones
and the STROBE will start flashing again.
Local Internal Router Mute/Acknowledgement of an Alarm
Press the ALARM button on an Internal Router. This only mutes the man overboard
alarm locally.