11
5. CONFIGURATION POSSIBILITIES
This chapter describes the possible settings in the Mobeye MS100EK.
5.1 INSTALLATION CODE
The installation code is the 4-digit code for switching on/off and programming the settings or
activating
the special functions. Factory default is “1111”. It is possible to change the code to
any 4-digit number. Please change the code to make the unit more secure.
5.2 USER CODE
The Mobeye MS100EK offers the possibility to set a personal 4-digit user code, for just arming
and disarming the system. It is not possible to change the settings with the user code. The
system needs to be switched on and off using the same code; the installation code and user
code are not interchangeable.
Factory settings for the user code is “8888”. This code can be
changed by the installation code or user code (menu number 50). We recommend that you
change this code to make the unit more secure.
5.3 TELEPHONE NUMBERS
Up to five telephone numbers can be programmed in to the Mobeye MS100EK. In the event of
an alarm the Mobeye MS100EK first sends an SMS text message to all numbers, next they are
called. It is possible to confirm the call, after which the other numbers will not be called anymore.
Note: the first telephone number is required, the others are optional.
5.4 SMS ON/OFF
By default, the Mobeye MS100EK sends alarm notifications via text message and calls to the
preset contact persons. By turning off the SMS, the unit will only call after the sensors send an
alarm.
5.5 CALL ON/OFF
By default, the Mobeye MS100EK sends alarm notifications via text message and calls to the
preset contact persons. By turning off the CALL, the unit will only send an SMS text message as
alarm notification. It is not possible to switch off both the SMS and the call.
5.6 INTERVAL TEST MESSAGE
The Mobeye MS100EK can send test messages. Through these
‘keep alive’ reports you will be
informed about the status of your Mobeye MS100EK. You can set the interval between the test
reports. This is adjustable between 0 (no test reported) and 30 (every 30 days a test message).
Note when MS100EK is battery-operated: the interval of 1 day will result in a daily test message;
the exact time between the messages will be about 24 hours.
The smaller the interval between the test reports, the shorter is the battery life. The test
message only works if the system is on.
5.7 SET ACTUAL TIME AND DATE
If the system is to be armed automatically, the internal clock time needs to be correct. Some
Telecom providers offer this in the network, to be synchronised by the Mobeye MS100EK during
the start-up and after sending test messages. It is possible to set the time and date manually. To
view the clock time, send a list of the settings to the first programmed phone number (CODE
MENU 10 OK).