Connect the external power adapter (or any other regulated  9-32VDC 
power  supply)  to  the  power  input  of  the  connector  (press  on  the 
orange pins for connecting the wires): 
 

 

V+ (black lead with white stripe) to “+” 

 

Ground (black lead) to “-“ 

 
If using the Mobeye mains adapter (Mobeye article 10027):  
The black wire with the white line 

is “+”, the other black wire is “-“. 

2.4 CONNECT THE BACK-UP BATTERY  

For  back-up  power,  in  the  situation  that  the  external  power  was 
cut, a rechargeable Mobeye battery can be connected.  
 
Attach  the  terminal  of  the  battery  to  the  white  connector.  The 
battery can be fixed with tie wraps or Velcro. 
 
If the power falls out, the unit will keep sits functions and a power 
failure  message  can  be  sent.  The  GSM  module  remains  open 
and the sensor inputs remain active. The back-up battery is able 
to power the module for at least 24 hours.  
 
Close the Mobeye MS100EK using the 4 screws. 

2.5 PROGRAM THE PHONE NUMBERS 

You need to program at least one phone number in the unit as alarm number. 

 

 

Enter your 4 digit code (factory setting: “1111”) 

 

Press “menu” 

 

Enter “101”  

 

Press “OK” 

  Enter the phone number (e.g. 0712345678 or 0044712345678) 

 

Press “OK” 

 

The  light  turns  green  and  a  confirmation  melody  is  played.  The  Mobeye  MS100EK  is  ready  to 
use. 

2.6 CHECK THE SETTINGS 

The  settings  can  be  sent  to  the  programmed  telephone  number  as  SMS  text  message.  In  this 
way you also check the correct working of the SIM card. 

 

Enter your 4 digit code (factory setting: “1111”) 

 

Press “menu” 

 

Enter “10”  

 

Press “OK” 

 
Within ca. 30 seconds the programmed phone number (TEL1) will receive the list with settings. 

2.7 SWITCHING ON 

The  Mobeye  MS100EK  is  switched  on  automatically  after  programming  the  first  telephone 
number. To switch on/off manually, please refer to 2.8. 

+ -

 

Summary of Contents for MS100EK

Page 1: ...Installation manual Mobeye MS100EK GSM Measure Control and Alarm module SW version 7 n...

Page 2: ......

Page 3: ...6 4 SMS ON OFF 11 6 5 CALL ON OFF 11 6 6 Interval test message 11 6 7 Set actual time and date 11 6 8 Automatic time based arm disarm 12 6 9 identification text 12 6 10 Alarm text 12 6 11 Input type 1...

Page 4: ...2...

Page 5: ...ternal use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where any inflammable gases v...

Page 6: ...grammed The SMS message contains the text Mobeye alarm 1 or Mobeye alarm 2 As soon as the inputs leave the alarm status an SMS text message is sent to the set telephone numbers containing the text suc...

Page 7: ...d at least once a month Open the back cover Insert the SIM card in the holder For opening closing move the cover slightly 2 2 CONNECT A SENSOR Open the hole in the enclosure and insert the 2 wires of...

Page 8: ...n active The back up battery is able to power the module for at least 24 hours Close the Mobeye MS100EK using the 4 screws 2 5 PROGRAM THE PHONE NUMBERS You need to program at least one phone number i...

Page 9: ...message is sent to all programmed alarm numbers next a phone call is made to the numbers When you answer the phone a beep tone is heard Confirm using 1 It is possible to confirm the phone call by ans...

Page 10: ...ternal power source Please find below the architecture of the main unit Inputs External sensors can be connected to the inputs Upon closing or opening an input the Mobeye MS100EK will send an alarm me...

Page 11: ...the SMS to OFF just call 1111 MENU 12 OK 0 OK 4 2 CONFIGURATION VIA SMS TEXT MESSAGES Almost all options can be set via the keypad except the texts It is also possible to program by sending SMS comman...

Page 12: ...10 Or both commands in one message Example 1111 TEL2 4934578692 CALLALARM OFF Example To set the SMS to OFF just call 1111 CALLALARM OFF...

Page 13: ...OFF By default the Mobeye MS100EK sends alarm notifications via text message and calls to the preset contact persons By turning off the SMS the unit will only call after the sensors send an alarm 5 5...

Page 14: ...s soon as the terminals of the input are closed If the input is set to NC the alarm is triggered if the connection between the input terminals is broken The default input type is set to NO 5 12 INPUT...

Page 15: ...eing authorised To disable the need for authorised numbers the authorization option can be set to OFF Default is ON 5 17 DURATION OF OUTPUTS SWITCH OR PULSE TIMES If an output is used the time this ou...

Page 16: ...puts 2 Power failure Send SMS call 3 Power restored Send SMS 4 Input 1 triggered Send SMS call 5 Input 2 triggered Send SMS call 6 Input 1 restored Send SMS 7 Input 2 restored Send SMS The SMS texts a...

Page 17: ...ION1 REACTION2 REACTION3 Do not forget the space between CODE and the TRIGGER The Mobeye MS100EK will play a short melody to indicate a successful configuration In case of a wrong command a long beep...

Page 18: ...uence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its index number even if a rule with a previous number is deleted This will result in gap...

Page 19: ...nput type input 1 Keypad 71 0 off 1 NO 2 NC 1 NO SMS TYPEIN1 OFF NO NC Input type input 2 Keypad 72 0 off 1 NO 2 NC 1 NO SMS TYPEIN2 OFF NO NC Inactive time Input 1 Keypad 73 0 999 min 5 SMS INACTIVEI...

Page 20: ...OFF ON SMS AUTH Identification text Keypad SMS NAME 20 characters Mobeye Alarm text power failure Keypad SMS TEXT2 20 characters Power failure Alarm text power restored Keypad SMS TEXT3 20 characters...

Page 21: ...t advised to test the GSM signal strength Enter the installation code Press menu Press 512 Press OK The Mobeye MS100EK will search for all available networks It also checks the network strength of the...

Page 22: ...test No network is available belonging to the SIM cards provider Choose another network provider The light remains red You entered an incorrect installation or user code three times Wait 10 minutes a...

Page 23: ...2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low volta...

Page 24: ......

Reviews: