© MOBATIME
45 / 52
801317.00
•
You can check the firmware version in the terminal list after starting the clock.
13.2
Firmware update over Ethernet on NTP and PoE versions
•
Create a folder on the computer disk and copy "tftpd32.ini", "tftpd32.chm" and
"tftpd32.exe" in it. Copy the new firmware file "devapp.bin" as well.
•
Run "tftpd32.exe", let only the TFTP Server in the window Settings -> Global
Settings be active, don’t change other settings.
•
Using the Browse key, open choice of active directory and find the one which
contains the given firmware
•
Connect to the clock by the windows command
telnet
<clock IP address>
example: telnet 192.168.0.190
•
The page of telnet requesting will appear, after the password entered identification
of current software version and clock MAC address displays.
•
Enter the command
fu
in telnet window to start the automatic clock firmware
update from the "devapp.bin" file.
•
Information about sending file and its progress displays in the tftpd32 program
window after the command entering. Connection to telnet is ended automatically.
•
Wait about 1 minute after downloading the file. Connect the telnet to the clock
again.
•
After entering the password, check if the firmware version is corre
ct, if it isn’t, it is
necessary to repeat the whole procedure.
•
Close the telnet window and end the program tftpd32 with the command
exit
.
Summary of Contents for ECO-M-DK
Page 1: ... MOBATIME BE 801317 00 INSTRUCTION MANUAL State of the art technology digital clock ECO M DK ...
Page 8: ... MOBATIME 8 52 801317 00 2 3 Assembly diagram Single sided clock Double sided clock ...
Page 9: ... MOBATIME 9 52 801317 00 2 4 Mechanical drawing Single sided clock Double sided clock ...
Page 11: ... MOBATIME 11 52 801317 00 2 6 Control PCB ...
Page 50: ... MOBATIME 50 52 801317 00 ...
Page 51: ... MOBATIME 51 52 801317 00 ...