© MOBATIME
37 / 52
801317.00
10.5 Slave clock controlled by supervised RS485
Supervised RS485 line available on the DTS.480x timeservers offers exact time
synchronization as well as monitoring the correct function of connected slave clocks.
•
If the ECO-M-DK clock should be monitored set in menu item
P8
unique address
in the range 1 to 32. The value "L" means that the clocks are synchronized only
(without monitoring).
•
It is necessary to register the clock under the used address in DTS.
•
The time synchronization starts within a few tens of seconds after start-up.
•
Failure of slave clock function is signalized by an alarm in DTS.
•
On the RS485 you can use the jumper TRE - JP10 to connect the termination
resistor 120R between the signals A and B for the correct termination of RS485.
Summary of Contents for ECO-M-DK
Page 1: ... MOBATIME BE 801317 00 INSTRUCTION MANUAL State of the art technology digital clock ECO M DK ...
Page 8: ... MOBATIME 8 52 801317 00 2 3 Assembly diagram Single sided clock Double sided clock ...
Page 9: ... MOBATIME 9 52 801317 00 2 4 Mechanical drawing Single sided clock Double sided clock ...
Page 11: ... MOBATIME 11 52 801317 00 2 6 Control PCB ...
Page 50: ... MOBATIME 50 52 801317 00 ...