Error Codes
17.0
15
Fault
Reason
Required Action
CPU Error RAM
-CPU consistency check
failed
Replace PCB
CPU Error FLASH
CPU Error EEPROM
Run Error Scheduler
-Firmware Consistency
check failed.
Update Software or Replace
PCB
Code Error Framework
Code Error Application
MSP Command Corrupt
-Corrupt command was
received.
Connection with the PC
(Configurator program) went
wrong, try again.
MSP Command Unknown
-Unknown command was
received.
Connection with the PC
(Configurator program)
went wrong. Update Firm-
ware or update Configurator
Software. Try again.
MSP Sup Command
Unknown
-Unknown Sub
Command was
received.
MSP Argument Invalid
-Invalid argument
received.
MSP Device Not Ready
-Device as not ready
to receive an MSP
command.
MSP Device Wrong State
-The device is not able to
receive a command in the
current device state.
User
Adjustments
15.1
As a user or attendant, you can make a limited number of parameter adjustments
with the mo-Vis Configurator Software.
Although the number of parameters you can change as a user or attendant is
limited, we advise changing only parameters you are familiar with.
For a list of parameter settings, see
Section 18.0.