Troubleshooting
16.0
14
When a fault occurs the LED will start to flash. There is a long delay and then a
number of flashes with a short delay. Count the number of flashes and look up
the according code in the table below.
If the problem persists after intervening, please contact your dealer to assist with
the problem.
Flash Count
Reason
Required Action
1
-
-
2
-
-
3
Power Supply,
Under/Over Voltage
Check Power Connections
and power cable
4
Temp Sensor
Replace PCB
5
Power Switch
Replace PCB
6
ADC
Interanal Analog to
Digital Convertor
Replace PCB
7
Test failed or diagnostic
failed
Redo Tests
Replace PCB
8
CPU Fault
Replace PCB
9
Scheduler Fault
Update Software
Replace PCB
10
Coding Error
Update Software
Replace PCB