PIN FUNCTIONS 

 

 

 

P1 - Signal Connector 

Pin 

Name 

Description / Notes 

I/O 

+10V 3mA OUT 

±10 V @ 3 mA low power supply for customer use. Short circuit protected.  Reference ground 
common with signal ground. 

SIGNAL GND 

GND 

-10V 3mA OUT 

+REF IN 

Differential Reference Input (±10 V Operating Range, ±15 V Maximum Input) 

-REF IN 

-TACH IN 

Negative Tachometer Input (Maximum ±60 V). Use signal ground for positive input. 

VEL MONITOR OUT 

Velocity Monitor. Analog output proportional to motor speed. In Encoder Velocity mode, output is 
proportional to the encoder line frequency. Encoder Velocity scaling is 22 kHz/V. In Hall Velocity mode, 
output is proportional to the Hall frequency. Hall Velocity scaling is 100 Hz/V. 

CURR MONITOR OUT 

Current Monitor. Analog output signal proportional to the actual current output. Scaling is 8.05 A/V by 
default but may be reduced by half this value by setting DIP switch SW1-3 to OFF (see Hardware 
Setting section below). Measure relative to power ground. 

INHIBIT / ENABLE 

TTL level (+5 V) inhibit/enable input. Pull to ground to inhibit drive (SW1-2 ON). Pull to ground 
to enable drive (SW1-2 OFF). Inhibit turns off all power devices. 

10 

+V HALL 30mA OUT 

Low Power Supply For Hall Sensors (+6 V @ 30 mA). Referenced to signal ground. Short circuit 
protected. 

11 

GND 

Signal Ground 

GND 

12 

HALL 1 

Single-ended Hall/Commutation Sensor Inputs (+5 V logic level). Leave open for brushed motors. 

13 

HALL 2 

14 

HALL 3 

15 

CURR REF OUT 

Measures the command signal to the internal current-loop. This pin has a maximum output of 

±

7.25 V when the drive outputs maximum peak current. Measure relative to power ground. 

 

16 

FAULT OUT 

TTL level (+5 V) output becomes high when power devices are disabled due to at least one of the 
following conditions: inhibit, invalid Hall state, output short circuit, over voltage, over temperature, 
power-up reset. 

 

P2 - Power Connector 

Pin 

Name 

Description / Notes 

I/O 

Motor Phase A 

Motor Phase B 

Motor Phase C 

POWER GND 

Power Ground (Common With Signal Ground) 

PGND 

HIGH VOLTAGE 

DC Power Input 

 
 

P3 

 Feedback Connector 

Pin 

Name 

Description / Notes 

I/O 

+5V 

Low Power Supply for Encoder (+5V). Internally connected to P1-10. Total current available from P3-1 
to P1-10 is 150 mA. Referenced to signal ground. Sort circuit protected. 

CHANNEL A 

Single-ended encoder channel A input. +5 V logic level. 

NC 

Not Connected (Reserved) 

CHANNEL B 

Single-ended encoder channel B input. +5 V logic level. 

SIGNAL GND 

Signal Ground 

SGND 

 

MIDWEST M

O

TION

 P

RODUCTS

 

Summary of Contents for SA-2550A

Page 1: ...nsors or a tachometer for velocity control Continuous Current 25 A Supply Voltage 20 80 VDC Features Four Quadrant RegenerativeOperation DIP Switch Selectable Modes DIP Switch Configurable Loop Tuning...

Page 2: ...Regenerative Braking with the Servo Amplifier 13 Loop Tuning Switch Functions 16 Mechanical Information 17 Mounting Dimensions 18 Troubleshooting Guide Red LED Causes and Solutions 19 Current Loop Tun...

Page 3: ...on electronics UL registered under file number E140173 Note that machine components compliant with UL are considered UL registered as opposed to UL listed as would be the case for commercialproducts C...

Page 4: ...pported Three Phase Brushless Single Phase Brushed Voice Coil Inductive Load Hardware Protection Over Current Over Temperature Over Voltage Under Voltage Short Circuit Phase Phase Phase Ground Primary...

Page 5: ...ve SW1 2 ON Pull to ground to enable drive SW1 2 OFF Inhibit turns off all power devices I 10 V HALL 30mA OUT Low Power Supply For Hall Sensors 6 V 30 mA Referenced to signal ground Short circuit prot...

Page 6: ...feedback polarity may be required to prevent a motor run away condition Standard Inverted 8 Mode Selection See mode selection table below 9 Reserved 10 60 120 degree commutation phasing setting 120 d...

Page 7: ...5 OFF ON OFF ON OFF ON OFF ON SW4 6 OFF OFF ON ON OFF OFF ON ON SW4 7 OFF OFF OFF OFF ON ON ON ON Peak and Continuous Current Scaling Table Default switch settings are shaded Switch Peak and Continuo...

Page 8: ...nd output current to the motor phases are the same amplitude Due to the nature of the MMP SA 2550A the input and output currents usually correlate but are not always equal To ensure the motor is recei...

Page 9: ...ecifications table page 4 As long as the input frequency is no less than 10 Hz and does not exceed the maximum frequency the servo amplifier is able to control speed smoothly Typically an encoder reso...

Page 10: ...VDC is used in place of a potentiometer then wire as shown below Remove connection to P1 1 and connect the signal positive to pin 5 for 0 100 POT effect Ensure VCOM is grounded to P1 2 Figure 2 Encode...

Page 11: ...toward the outside of the servo amplifier as shown in the picture below Note Make sure to disconnect all Hall sensor inputs Figure 1 120 60 Phasing Switch Example Motor Connections With the 120 60 PHA...

Page 12: ...P1 4 FWD 0 100 CW P1 1 P1 2 P1 4 REV 0 100 CW P1 3 P1 2 P1 5 REV 0 100 CW P1 2 P1 3 P1 4 FWD 100 0 CCW P1 2 P1 1 P1 5 FWD 100 0 CCW P1 2 P1 1 P1 4 REV 100 0 CCW P1 2 P1 3 P1 5 REV 100 0 CCW Assumes th...

Page 13: ...egenerated energy can charge the power supply capacitors to levels above that of the drive over voltage shutdown level If the power supply capacitance is unable to handle this excess energy or if it i...

Page 14: ...load J m mass of the load kg g gravitational acceleration 9 81 m s2 h vertical height of the load m During regeneration the kinetic and potential energy will be stored in the power supply s capacitor...

Page 15: ...y the for a shunt regulator by operating the servo drive under the worst case braking and deceleration conditions If the drive shuts off due to over voltage a shunt regulator is necessary Continuous R...

Page 16: ...OFF OFF ON ON OFF OFF ON ON OFF OFF SW3 3 ON ON ON ON OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF SW3 4 ON ON ON ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF SW3 5 ON ON ON ON ON ON ON ON ON ON ON...

Page 17: ...e Yes 15 VEL MONITOR OUT 13 HALL 2 11 GND 9 INHIBIT ENABLE 7 ENCODER A IN 5 REF IN 3 10V 3mA OUT 1 10V 3mA OUT 2 SIGNAL GND 4 REF IN 6 ENCODER B IN 8 CURRENT MONITOR 10 V HALL 30mA OUT 12 HALL 1 14 HA...

Page 18: ...SA 2550A Page 18 of 24 Midwest Motion Products DESIGN MANUFACTURING DISTRIBUTION MOTION CONTROL EQUIPMENT www midwestmotion com email sales midwestmotion com MOUNTING DIMENSIONS MIDWEST MOTION PRODUC...

Page 19: ...using a brushless motor connect Hall sensor inputs and set the 60 120 phasing switch to the correct position according to the motor Apply power to the drive and rotate the motor by hand If the LED is...

Page 20: ...ce in the table below 60 Degree 120 Degree 60 Degree 120 Degree Hall A Hall B Hall C Hall A Hall B Hall C 1 0 0 1 0 0 1 1 0 1 1 0 1 1 1 0 1 0 Valid 0 1 1 0 1 1 Green 0 0 1 0 0 1 LED 0 0 0 1 0 1 1 0 1...

Page 21: ...ower ground and AC ground Make sure the motor phases are not shorting to AC ground through the motor housing or shielding on the motor power cable Over current An over current fault will occur if comm...

Page 22: ...near the drive s upper voltage limit Low power supply voltage power supply voltage is near the drive s lower voltage limit To perform current loop tuning first locate the relevant potentiometer POT 1...

Page 23: ...tiometers are preset the correlation of command voltage to motor speed may result in less control of motor speed then desired A typical command curve would appear as below if potentiometer at full CCW...

Page 24: ...mail sales midwestmotion com The respective potentiometers have the following effects on the command curve As noted in the Potentiometer Functions table on page 6 each potentiometer has approximately...

Reviews: