Chann.
Generator signal
Level (RMS) Frequency
Settings at VM30-H
Typical display values (m/s²)
X
Y
Z
Max. error
Filters at reference frequency:
XYZ
5 mV
79.58 Hz
Wh, HV, A(T), G=1000
0.101
0.101
0.101
3 %
XYZ
5 mV
15.92 Hz
Wb, HV, A(T), G=1000
0.4063
0.4063
0.4063
3 %
Z
5 mV
15.92 Hz
Wc, HV, A(T), G=1000
0.2573
3 %
XY
5 mV
15.92 Hz
Wd, HV, A(T), G=1000
0.06305 0.06305
5 %
XYZ
5 mV
15.92 Hz
We, HV, A(T), G=1000
0.032
0.032
0.032
7 %
XYZ
5 mV
15.92 Hz
Wg, HV, A(T), G=1000
0.243
0.243
0.243
3 %
XYZ
5 mV
15.92 Hz
Wj HV, A(T), G=1000
0.5095
0.5095
0.5095
3 %
XYZ
5 mV
15.92 Hz
Wk, HV, A(T), G=1000
0.3859
0.3859
0.3859
3 %
XYZ
5 mV
15.92 Hz
Wm, HV, A(T), G=1000
0.1681
0.1681
0.1681
3 %
XYZ
5 mV
15.92 Hz
0,4-100 Hz, a, A(T), G=1000
0.500
0.500
0.500
3 %
XYZ
5 mV
15.92 Hz 0.4-100 Hz, a, RMS, G=1000
0.500
0.500
0.500
3 %
Cross-talk between channels X, Y and Z:
X
500 mV
80 Hz
0.4-1250 Hz, a, RMS, G=10
50.0
<0.25
<0.25
Y
500 mV
80 Hz
0.4-1250 Hz, a, RMS, G=10
<0.25
50.0
<0.25
Z
500 mV
80 Hz
0.4-1250 Hz, a, RMS, G=10
<0.25
<0.25
50
Chann.
Generator signal
Level (RMS) Frequency
Settings at VM30-H
Typical display values (m/s²)
X Y Z
Max. error
XYZ 1000 mV
80 Hz
0.4-1250 Hz, a, RMS, G=1
100
100
100
3 %
XYZ
316 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=10
31.6
31.6
31.6
3 %
XYZ
100 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=10
10.0
10.0
10.0
3 %
XYZ 31.6 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=100
3.16
3.16
3.16
3 %
XYZ
10 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=100
1.00
1.00
1.00
3 %
XYZ 3.16 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=1000
0.316
0.316
0.316
3 %
XYZ
1 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=1000
0.100
0.100
0.100
3 %
XYZ 2000 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=1
200
200
200
3 %
XYZ
632 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=10
63.2
63.2
63.2
3 %
XYZ
200 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=10
20.0
20.0
20.0
3 %
XYZ 63.2 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=100
6.32
6.32
6.32
3 %
XYZ
20 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=100
2.00
2.00
2.00
3 %
XYZ 6.32 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=1000
0.632
0.632
0.632
3 %
XYZ
2 mV
80 Hz
0.4- 1250 Hz, a, RMS, G=1000
0.200
0.200
0.200
3 %
Filter characteristics at selected frequencies:
XYZ
500 mV
1 Hz
Wb, HV, RMS, G=10
19,3
19,3
19,3
11 %
XYZ
500 mV
1 Hz
Wd+Wc, HV, RMS, G=10
50,6
50,6
49,6
21 %
XYZ
500 mV
1 Hz
Wd+Wk, HV, RMS, G=10
50,6
50,6
24,1
21 %
XYZ
500 mV
1 Hz
We, HV, RMS, G=10
44,0
44,0
44,0
11 %
XYZ
500 mV
1 Hz
Wg, HV, RMS, G=10
21,2
21,2
21,2
50 %
XYZ
500 mV
1 Hz
Wh, HV, RMS, G=10
1,3
1,3
1,3
-100 %
XYZ
500 mV
1 Hz
Wj, HV, RMS, G=10
24,2
24,2
24,2
11 %
XYZ
500 mV
1 Hz
Wk, HV, RMS, G=10
24,1
24,1
24,1
21 %
XYZ
500 mV
1 Hz
Wm, HV, RMS, G=10
41,6
41,6
41,6
21 %
XYZ
500 mV
4 Hz
Wb, HV, RMS, G=10
44,3
44,3
44,3
11 %
XYZ
500 mV
4 Hz
Wd+Wc, HV, RMS, G=10
25,7
25,7
51,2
11 %
XYZ
500 mV
4 Hz
Wd+Wk, HV, RMS, G=10
25,7
25,7
48,2
11 %
XYZ
500 mV
4 Hz
We, HV, RMS, G=10
12,7
12,7
12,7
11 %
XYZ
500 mV
4 Hz
Wg, HV, RMS, G=10
50,2
50,2
50,2
11 %
XYZ
500 mV
4 Hz
Wh, HV, RMS, G=10
18,8
18,8
18,8
11 %
XYZ
500 mV
4 Hz
Wj, HV, RMS, G=10
31,3
31,3
31,3
11 %
41