• Isolate the mains supply to the fitting
• Remove the capping nut, and using plyers pull out the protective insert from the fitting
(see Fig. 4)
• Align the pins on the sensor, push onto the fitting, and tighten ensuring a good seal is
made. Do not overtighten
• The rotation and tilt of both sensors can be adjusted once fitted. For the PIR accessory,
please ensure it is positioned with the adjustment dials at the bottom
• With the LUX set to Daytime, and the TIME set to the minimum, perform a walk test to
set the SENS setting so the required detection area is covered. Then set the TIME and
LUX controls to the desired settings:
PIR / MICROWAVE SENSOR ACCESSORY
Fig. 4
•
Align the pins on the sensor, push onto the fitting, and tighten ensuring a good seal is made. Do not
overtighten
•
The rotation and tilt of both sensors can be adjusted once fitted. For the PIR accessory, please ensure
it is positioned with the adjustment dials at the bottom
•
With the LUX set to Daytime, and the TIME set to the minimum, perform a walk test to set the SENS
setting so the required detection area is covered. Then set the TIME and LUX controls to the desired
settings:
Setting
FLNMIC
FLNPIR
SENS
Minimum: up to 4m
Maximum: up to 12m
Minimum: up to 5m
Maximum: up to 10m
LUX
Minimum: 3 lux
Maximum: 2000 lux
Minimum: 10 lux
Maximum: 2000 lux
TIME
Minimum: 10 sec
Maximum: 15 min
Minimum: 10 sec
Maximum: 7 min
Override Function (FLNPIR only)
•
Switch the mains supply to the fitting OFF-ON-OFF-ON within three seconds. The light flashes ON-
OFF-ON to indicate that it is in override mode. To return to automatic mode, switch the mains supply to
the fitting off for at least 10 seconds, then switch on again
•
The FLNMIC has no override function
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance
testing. Irreparable damage will occur if this instruction is not followed.
GENERAL
The LED lamps fitted in this product are non-replaceable. The product should be recycled in the correct manner
when it reaches the end of its life. Check local authorities for where facilities exist.
Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not
use aggressive cleaning products or solvents which may damage the product.
Do not use any source of high-pressure washers to maintain or clean this luminaire.
This product is non-dimmable.
WARRANTY
This product has a warranty of 3 years from date of purchase. Failure to install this product in accordance with
the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will
invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of
purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation
costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve
the right to alter product specification without prior notice.
Fig. 4