SERVICE TROUBLE SHOOTING
| 19
10. No Vibration But Drive Pressure at 2500 PSI When Put in Vibrate Mode
Assuming the drive quick disconnects are not faulty and connected full and correctly,
there may be a locked bearing, gear, or motor.
11. V-2Esc Not Coming Up To Speed and/or Pressure Very Low
Relief valve in the directional control valve may be clogged. May have a worn out pump
or motor.
12. V-2Esc Frequency Low But Pressure High
The motor seal might have blown filling the V-2Esc Exciter Case with oil. Check the lube
oil level. Might have a bearing failure. Check for excessive exciter case heat.
Summary of Contents for V-2Esc
Page 23: ...DRAWINGS AND PARTS LISTS 21 A V 2ESC GENERAL ASSEMBLY AND PARTS LIST 402 06 00...
Page 26: ...24 DRAWINGS AND PARTS LISTS B V 2ESC HYDRAULIC CLAMP ASSEMBLY AND PARTS LIST 402 05 23...
Page 28: ...26 DRAWINGS AND PARTS LISTS C SIDE CLAMP ASSEMBLY AND PARTS LIST 495 05 97...
Page 30: ...28 DRAWINGS AND PARTS LISTS C SIDE CLAMP ASSEMBLY AND PARTS LIST 495 05 97...
Page 32: ...30 DRAWINGS AND PARTS LISTS E HP 85T3 POWER UNIT GENERAL ASSEMBLY AND PARTS LIST 403 06 00...
Page 36: ...34 DRAWINGS AND PARTS LISTS F HP 85T3 HYDRAULIC SCHEMATIC AND PARTS LIST 403 01 00...