7.1 Removal from System
Prior to removing the entire valve or a valve’s actuator assembly from a
vacuum system, it is necessary to bring the system up to atmospheric
pressure. Purge and vent hazardous gasses appropriately.
7.1.1 Pneumatic Version
Detach the pneumatic supply. To avoid injury, be sure the pneumatic line is
depressurized prior to disconnection from the valve.
If the valve is equipped with the solenoid operated pilot valve it will be
necessary to disconnect these leads. To avoid electrocution, be sure the
power to the pilot valve is off prior to disconnection. Refer to section 7.5 for
details on solenoid pilot valve repair.
If the valve is equipped with limit switches, the limit switch assembly may be
removed from the valve without disconnecting the leads. For details on this
procedure, refer to section 7.4.
Loosen and remove the clamps or bolts on the port flanges. If possible,
pull one of the flanges mating to a port flange directly away from the
valve to allow removal of the valve without scraping sealing surfaces.
Replace the protective plastic caps on the port flanges or cover the ports
with aluminum foil.
Avoid touching the interior surfaces of the valve. Moisture, skin oils, and dirt
may contaminate the interior of the valve, affecting its performance upon
reinstallation, and/or, more importantly, films deposited on the interior
surfaces of the valve may be toxic.
7.1.2 Manual Version
Loosen and remove the clamps or bolts on the port flanges. If possible,
pull one of the flanges mating to a port flange directly away from the
valve to allow removal of the valve without scraping sealing surfaces.
Replace the protective plastic caps on the port flanges or cover the ports
with aluminum foil.
Avoid touching the interior surfaces of the valve. Moisture, skin oils, and dirt
may contaminate the interior of the valve, affecting its performance upon
reinstallation, and/or, more importantly, films deposited on the interior
surfaces of the valve may be toxic.