pg. 23
User Switch Command
The User Switch function can be disabled to prevent accidental execution of zero and atmospheric
adjustments.
Command:
@253SW!OFF;FF
Command values:
ON,OFF
Command reply:
@253ACK;FF
Query:
@253SW?;FF
Query reply:
@253ACKON;FF
Factory default:
ON
Transducer test
The transducer test command can be used to visually identify a transducer. If the test mode is enabled the
LED will flash with a 1 sec. cycle.
Command:
@253TST!ON;FF
Command values:
ON,OFF
Command reply:
@253ACK;FF
Query:
@253TST?;FF
Query reply:
@253ACKON;FF
Factory default:
OFF
Status Query Commands
Query replies are examples that might be different from actual transducer reply.
Device Type - DT
Specifies transducer device type name:
Query:
@253DT?;FF
Query reply:
@253ACKDUALTRANS;FF
Firmware Version - FV
Specifies transducer firmware version:
Query:
@253FV?;FF
Query reply:
@253ACK1.00;FF
Hardware Version - HV
Specifies transducer hardware version:
Query:
@253HV?;FF
Query reply:
@253ACKA;FF
Manufacturer - MF
Specifies transducer manufacturer:
Query:
@253MF?;FF
Query reply:
@253ACKMKS;FF
Model - MD
Specifies transducer model number:
Query:
@253MD?;FF
Query reply:
@253ACK910;FF
Part Number - PN
Specifies transducer part number:
Query:
@253PN?;FF
Query reply:
@253ACK910-11030;FF