background image

Safety information

10

Operating instructions

2 Safety information

The unit complies with applicable safety standards. Residual risks
associated with operation or risks resulting from incorrect operation
cannot be ruled out and are mentioned specifically in the safety
instructions and warnings.

The operator must be familiar with regional regulations and observe
them.

Operation

During operation, the following group of individuals must be
supervised by an individual who is responsible for safety:

Individuals with physical, sensory, or mental handicaps, or who
lack the knowledge and experience to operate the unit properly.

The supervising individual must be familiar with the unit and the risks
associated with it.

Hot surfaces Risk of burns from hot surfaces

Protect arms and hands by wearing suitable protective gloves.

Do not touch heating elements, hot surfaces or accessories
immediately after use.

Allow surfaces to cool prior to cleaning.

Hot liquids Risk of scalding from hot oil

Protect arms and hands by wearing suitable protective gloves.

Do not operate the unit without the receiver tank.

Risk of chemical burns from evaporating cleaners

Follow the instructions of the cleaning agent manufacturer.

Defective unit Risk of injury from a defective unit

Use gas shut-off valve to isolate unit from gas supply.

Do not operate a defective unit.

Allow only an authorized technician to repair the unit.

Escaping gas or exhaust

gas

Risk of asphyxiation and explosion from escaping gas

Follow the rules of conduct when the smell of gas is detected (see
"Rules of conduct when the smell of gas is detected").

Risk of asphyxiation and poisoning from exhaust gases

Ensure that air inlet openings are free and that a sufficient amount
of the necessary combustion air is supplied.

Ensure that the exhaust gas outlet openings are free and that the
exhaust gases are discharged properly.

Fire prevention Risk of fire from dirt and grease deposits

Clean the unit when finished using it.

1001064120ABBE--

Summary of Contents for Argentina 1

Page 1: ...type Model Argentina 1 Argentina 2 Gas Floor standing unit OPGGSGARG HLGGSGARG Countertop unit SLGGSGARG Weld in ESGGSGARG Translation from the original document 1001064120ABDE 07 06 2017 1001064120A...

Page 2: ...Pilot burner monitoring b Burner control knob d Piezo pilot ignitor button a b e d c c d e b a Image Argentina 2 lava stone grill a Piezo pilot ignitor button d Burner control knob b Heat zone identi...

Page 3: ...49 5331 89 280 Internet www mkn eu Copyright All rights to text graphics and pictures in this documentation are held by MKN Maschinenfabrik Kurt Neubauer GmbH Co KG Distribution or duplication is onl...

Page 4: ...unit on and off 17 5 2 1 Switching on 17 5 2 2 Switching off 18 5 3 Basic functions 18 5 3 1 Setting the grate height 18 5 3 2 Loading in the water 19 5 3 3 Adjusting the output 19 5 3 4 Placing the...

Page 5: ...tory of contents 5 Operating instructions 7 2 Nameplate 25 8 Carrying out maintenance 26 9 Disposing of the unit in an environmentally responsible manner 27 10 Manufacturer s declaration 28 1001064120...

Page 6: ...Directory of contents 6 Operating instructions 1001064120ABBE...

Page 7: ...he operating instructions available to the operator at all times at the operating site of the unit Insert any supplements from the manufacturer Keep the operating instructions throughout the service l...

Page 8: ...ON Dangerous situation Failure to comply can lead to slight or moderately severe injuries ATTENTION Physical damage Failure to comply can cause physical damage Notes for better understanding and opera...

Page 9: ...ther chemicals Heating of warmer plates Heating rooms Direct grilling on the lava stones Direct grilling on the support grate of the lava stones Grilling in pots pans or aluminium bowls on covered gra...

Page 10: ...fter use Allow surfaces to cool prior to cleaning Hot liquids Risk of scalding from hot oil Protect arms and hands by wearing suitable protective gloves Do not operate the unit without the receiver ta...

Page 11: ...measures when handling aggressive cleaning agents Risk of falling on smooth floors Keep the floor in front of the unit clean and dry Risk of physical damage from improper cleaning Clean the unit afte...

Page 12: ...or aluminium materials on the grilling stones Do not put pots pans or aluminium trays on the grates or grilling stones Do not grill directly on the grilling stones Do not operate the unit without gril...

Page 13: ...meter at the main supply and if possible at the units Warn other individuals in the building Call out and knock do not ring doorbells Leave the building and prevent entry by others Notify the gas util...

Page 14: ...or frying fast fry food and for grilling 4 1 Overview of the unit 4 1 1 Floor standing unit a b c d e f g h i j Image Argentina 2 gas lava stone grill a Grilling surface with grate f Nameplate and gas...

Page 15: ...b c d e f g h i Image Argentina 2 gas lava stone grill a Grilling surface with grate f Collection container b Lava stone grate g Collection plate c Front grate holder h Lava stone d Nameplate and gas...

Page 16: ...gas supply Ignition Gas supply for pilot burner is released the burner is switched off Output Set the burner output Piezo pilot ignitor button Ignite pilot burner Flame monitoring inspection port Mon...

Page 17: ...hut off valve on the unit is closed 1 Open the gas shut off valve on the unit 2 Press the Burner control knob and turn it to the setting 3 Keep the Burner control knob pressed on the setting Gas flows...

Page 18: ...c functions 5 3 1 Setting the grate height The grate height adjustment can be set at 4 different drain angles The distance from the lava stones is also set a b c d e Image Grate height adjustment a Un...

Page 19: ...sert the collection container again 5 3 3 Adjusting the output During operation the Burner control knob is safeguarded against unintentional shifting to the setting Increase output Turn the Burner con...

Page 20: ...e lava stones 3 Replace the grate 5 4 Grilling Requirements Water is loaded Collection container inserted Grate placed in position Grilling surface cleaned 1 Brush the grate thinly with frying fat or...

Page 21: ...t of operation for a longer period of time the unit must be checked by an expert who is approved by the gas utility 1 Press the Burner control knob and turn it to the setting The burner is switched of...

Page 22: ...grease starch and protein deposits Only expose parts made from non rusting steel to brief contact with highly acidic foods spices salts or the like Avoid damaging the stainless steel surface with othe...

Page 23: ...ainless steel cleaner 4 Rinse with clear water and then dry 5 Brush the grate thinly with frying fat or oil 6 Replace the grate 6 5 Cleaning the collection container Requirement Collection container c...

Page 24: ...spection intervals Have inspections performed by a capable user In the event of damage or signs of wear contact customer service immediately and stop using the unit Requirements Unit switched off and...

Page 25: ...tomer service Burner control knob is on the setting Set the output Burner control knob is defective Close the gas shut off valve on the unit Contact Customer service Piezo pilot ignitor button is defe...

Page 26: ...Carrying out maintenance 26 Operating instructions 8 Carrying out maintenance The unit is maintenance free there are no maintenance requirements 1001064120ABBE...

Page 27: ...alth and pollute the environment Dispose of the unit in accordance with local regulations for used appliances Clarify any open questions with the responsible agencies for instance solid waste manageme...

Page 28: ...s Directive 2011 65 EU RoHS dated 01 July 2011 REGULATION EC No 1935 2004 dated 27 October 2004 on materials and objects which are intended to come into contact with food We hereby declare that the li...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...www mkn eu...

Reviews: