Operating the unit
21
Operating instructions
5.5 Pauses and end of use
Switch off the unit during pauses and at end of use.
5.5.1 Brief pauses
When restarting the unit after pauses, first check the function of
the pilot burner in order to prevent a flash fire.
1. Press the
Burner
control knob and turn it to the "
" setting.
The burner is switched off.
The pilot burner remains on.
2. Continuing after a pause in operation:
3. Press the
Burner
control knob and turn it to the "
" setting.
The burner is ignited.
The burner burns at full load.
Heat zone is on.
5.5.2 Long pauses and end of use
After being out of operation for a longer period of time, the unit
must be checked by an expert, who is approved by the gas
utility.
1. Press the
Burner
control knob and turn it to the " " setting.
The burner is switched off.
The pilot burner is switched off.
The unit is off.
2. Close the gas shut-off valve on the unit.
Unit not in operation.
5.6 Emptying the collection container
CAUTION
Risk of scalding from hot liquids
•
Allow the collection container to cool down before emptying
it.
•
Protect arms and hands by wearing suitable protective
gloves.
Requirements
Collection container cooled down
1. Remove the collection container carefully from the unit and empty
it properly.
2. Remove the frying residue and wipe the collection container out
with kitchen paper.
3. Insert the empty collection container.
1001064120ABBE--