tion of each of them, bands whose start time can be
adjusted throughout the day. The boiler will activate
and deactivate independently (a situation highlighted
by the presence or absence of the icon ), accor-
ding to the instructions given to it by the thermostat,
to ensure the maintenance of the set temperature in
the active band at any time. It is only necessary to
set the start time of each band and the temperature
that must be guaranteed during its course: the du-
ration, as well as the end time, will depend on the
start time of the next one. The six bands, and their
conventional meaning, are summarized in the table
below:
#
Icon
Standard
condition
Start time Duration End time Default
temp.
1
Awakening
6:00:00
1:59:59
7:59:59
20° C
2
Morning exit
8:00:00
3:29:59
11:29:59
15° C
3
Mid-day return 11:30:00
1:59:59
13:29:59
15° C
4
Mid-day exit
13:30:00
3:29:59
16:59:59
15° C
5
Evening return 17:00:00
4:59:59
21:59:59
22° C
6
Night
22:00:00
7:59:59
5:59:59
the next
day
15° C