2. Open Vent Cap (X) on Water Tank before operating the equipment.
STEP 2 - ATTACHING WATER TANK TO SAW
V
1. Insert other end of the Hose (W) into Coupling (V) attaching to the Saw.
W
X
3. Turn on equipment to make sure fine mists are being delivered through both Misting Nozzles (Y).
Y
Note: Nozzles may be changed to provide additional water flow. The TX3 is shipped with 0.03mm misting nozzles installed on
the saw, with an additional pair of 1.0mm nozzles included (see contents table on page 14). If you are in need of more water flow
to control dust, the 1.0mm nozzles may be substituted. To remove a nozzle, simply unscrew it counterclockwise. If even more
water is needed, the nozzles can be removed completely, thus making a “flood” type saw. If running the saw without nozzles, the
water supply will diminish quickly. Keep an eye on the water level, so as not to run the pump when dry. Running the pump dry
will cause damage.