background image

CobraTig

®

 150 Owner's Manual

  -  Page 10

If the current weld program is a temporary, unsaved/modified program, the 

RECALL screen will be blank.  This indicates that the current weld program 
has not been saved to any location.  However, if the current weld program 
is from one of the saved locations, this screen will display the location it is 
presently saved at.

Press any button that does not contain the word EMPTY. Press WELD 
ORBITAL to return to that screen to begin welding with the saved 
procedure.

Section 10 

Save Program

Once a weld procedure has been developed, it is generally a good idea to 
save it for use at a later date.  In order to do this, simply press the SAVE 
PROGRAM button.  This will change to the SAVE USER MEMORY screen.

Help

 

Press this button to read a brief description of the SAVE menu button 
descriptions and functions.

Main Menu

 

Press this button to change to the MAIN MENU.

Weld Orbital

 

Press this button to change to the WELD ORBITAL screen.

Communication Menu

 

Press this button to change to the COMMUNICATION MENU.

Scroll Left

 

Each time this button is pressed, the locations of where each weld 
procedure is saved or can be saved to, will move three numbers to the 
left.

Those locations with the word EMPTY above the number, indicate that 
there is no weld procedure saved in that location.

Locations

When a location button is pressed, and if that location is already 
occupied with a weld procedure, another screen will appear with an 
OVERWRITE VERIFY message.

Summary of Contents for CobraTig 150 SM

Page 1: ...Product CobraTig Manual 091 0675 Serial 13110001 Voltage Rating 100 120 208 220 230 240VAC Revision Nov 2013 Rev B Model Number 254 153 254 252 CobraTig 150 SM Owner s Manual...

Page 2: ...4 Connections 3 Section 5 Operation 5 Section 6 Main Menu 6 Section 7 Weld Manual 6 Section 8 Weld Orbital 8 Section 9 Recall Program 9 Section 10 Save Program 10 Section 11 Auto Program Generator 11...

Page 3: ...r s Name MK Products Inc 16882 Armstrong Ave Irvine CA 92606 Declares that the product CobraTig 150 SM conforms to the following Directives and Standards Directives Low Voltage Directive 2006 95 EC El...

Page 4: ...d with or containing materials that emit toxic fumes should not be heated unless coating is removed form the work surface the area is well ventilated or the operator wears an air supplied respirator W...

Page 5: ...Notify your supplier Mixing gases NEVER try to mix any gases in a cylinder NEVER refill any cylinder Cylinder fittings should never be modified or exchanged 3 Hose Prohibited use Never use hose other...

Page 6: ...ther bare metal in the welding circuit or in ungrounded electrically HOT equipment can fatally shock a person whose body becomes a conductor DO NOT STAND SIT LIE LEAN ON OR TOUCH a wet surface when we...

Page 7: ......

Page 8: ...deal weld procedure through the use of our Automatic Procedure Generator Just enter the tube outside diameter and wall thickness The rest is automatic This version of CobraTig Software and Hardware ha...

Page 9: ...ion rates The water cooled narrow profile CopperHeads are lightweight and easy to handle for those awkward welds with limited access All MK weldheads can be utilized as bench mounted or remotely contr...

Page 10: ...the 1 4 hex head screws from the cover of the unit then lift the cover off Locate TB1 on the lower right rear side of the unit from the front Using the Phillips head screwdriver to change the taps fo...

Page 11: ...the Tool Bar select Send then select Send Firmware Upgrade to CobraTig Ctrl U Choose the correct COM port in accordance with your PC laptop from the CobraTig Communication dialog box Press Start If t...

Page 12: ...below The unit will remember the last screen that was on when it was powered off To start from the beginning it is best to calibrate the weldhead prior to starting Once the weldhead is calibrated pre...

Page 13: ...t will start with the last screen displayed Help Press this button to read a brief description of the MAIN MENU button descriptions and functions Section 7 Weld Manual From the MAIN MENU screen the WE...

Page 14: ...l UP scrolls the highlighted field from one demand parameter to the next demand parameter F5 Adjust Up increases the numerical value of the demand parameter selected As this button is pressed for each...

Page 15: ...rator APG Start Stop Pressing this button will start the prepurge gas flowing and start the welding procedure Main Menu Press this button to return to the MAIN MENU Print Weld Press the PRINT WELD but...

Page 16: ...eturn to the MAIN MENU Weld Orbital Press this button to return to the WELD ORBITAL screen Scroll Left Each time this button is pressed the locations of where each weld procedure is saved will move th...

Page 17: ...o do this simply press the SAVE PROGRAM button This will change to the SAVE USER MEMORY screen Help Press this button to read a brief description of the SAVE menu button descriptions and functions Mai...

Page 18: ...the bottom of the WELD ORBITAL screen Scroll Down Press this button in order to scroll the highlighted field from one DEMAND parameter down to the next Adjustment of each parameter is performed using...

Page 19: ...pressed thus bypassing any additional features and changing directly to the WELD ORBITAL screen Previous Entry Press this button to return to the previous field in order to change the entered value N...

Page 20: ...PRINTER STATUS field to read OK To load a new roll of paper slide printer tray straight out until it stops Disengage the Printer Drive Mechanism by lifting up the Drive Latch Arms on either side of t...

Page 21: ...LTS mode a Strip Chart will only printout if there were deviations in the weld sequence Section 13 Calibration Menu Prior to using the CobraTig 150 SM unit for welding it is generally a good idea to c...

Page 22: ...P and ADJUST DOWN buttons to select the rpm value required The HIGH and LOW values can never be equal A minimum of 1 0 rpm will separate the two values If the LOW value is increased the HIGH will incr...

Page 23: ...etting and press CURRENT START Once the 10 A arc is established use the ADJUST UP and ADJUST DOWN buttons to reach 2 50 mV on the multimeter Once this mV value is read press the 10 A button this will...

Page 24: ...t simply press the START RECEIVE button to saved the transmitting procedure then press the location number of where the procedure is to be saved If the procedure is saved to a location that is empty t...

Page 25: ...ast for the LCD screen This will make the display lighter as the number decreases Section 16 Diagnostic Menu This screen will show the units internal total on time diagnostics This includes number of...

Page 26: ...inute of the hour Once the end of the range is reached the sequence will revert again Range 0 59 Change Day Press to increase date of the month Range 1 31 Change Month Press to increase the change of...

Page 27: ...THIS PAGE INTENTIONALLY BLANK...

Page 28: ...DATE August 1 2010 16882 Armstrong Ave Irvine CA 92606 Tel 949 863 1234 Fax 949 474 1428 www mkproducts com...

Page 29: ...16882 ARMSTRONG AVE IRVINE CA 92606 TEL 949 863 1234 FAX 949 474 1428 WWW MKPRODUCTS COM...

Reviews: