SAFE USAGE OF THE PRODUCT 

 

When unpacking and before disposing of the carton, check there is no transportation damage before 
using the product. Should there be any damage caused by transportation, consult your dealer and do 
not use the apparatus. 
The product is for indoor use only, IP20. Use only in dry locations. Keep this device away from rain 
and moisture, excessive heat, humidity and dust. Do not allow contact with water or any other 
liquids. 
The product is not designed or intended to be mounted directly on to inflammable surfaces 
The product is only intended for installation, operation and maintenance by professional person. 
The  product  must be installed in a location with adequate ventilation, at least 50cm from adjacent 
wall surfaces. Be sure that no ventilation slots are blocked. 
Do not product the beam onto inflammable surfaces, minimum distance is 15m. 
Avoid direct exposure to the light from the lamp. The light is harmful to the eye. 
Do not attempt to dismantle or modify the projector in any way. 
Electrical connection must only be carried out by qualified personnel. 
Before installation, ensure that the voltage and frequency of power supply match the power 
requirements of the projector.   
It is essential that each projector is correctly earthed and that electrical installation conforms to all 
relevant standards. 
Do not connect this device to any other types of dimmer apparatus. 
Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the 
power-cord come into contact with other cables. Only handle the power-cord by the plug. Never pull 
out the plug by tugging the power-cord. 
Keep the light clean. Do not touch the light glasss with bare hands. 
The product should always be installed with a secondary safety fixing. On the projector base brink, 
there is a hole for the safety cord provided. It should be attached as shown in “installing the projector” 
section. 
The lamp used in this projector is a discharge lamp. After switching off don

,

t attempt to restart the 

projector until lamp has cooled, this will require approx 15 minutes. Switching the lamp on and off at 
short intervals will reduce the life of both the lamp and the projector. But occasional breaks will 
prolong the life of the lamp and projector. 
Never run the projector without a lamp. 
The light shall be changed if it has become damaged or thermally deformed or reached its life limit. 
Shields and lens shall be changed if they have become visibly damaged to such an extent than their 
effectiveness is impaired, for example by cracks or deep scratches. 

Exterior surface temperatures of the luminaire after 5 minutes operation is 70°,when steady state is achieved 140°

 

There is no user serviceable parts inside the projector, do not open the housing and never operate the product 

with the covers removed. 

If you have any questions, don’t hesitate to consult your dealer or manufacturer. 

 

Always disconnect from the mains, when the device is not in use or before cleaning  it or 

before attempting any maintenance work ! 

Summary of Contents for MJ-B380

Page 1: ...380 User manual PROFESSIONAL STAGE LIGHTING Thank you for choosing our beam moving head light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Page 2: ...tested completely and packed properly by the manufacturer Please make sure the packing and the unit are in good condition before installation and use Should there be any damage caused by transportation consult your dealer and do not use the unit Any damage caused by improper use will not be assumed by the manufacturer or dealer Attention Unceasingly carries on the product improvement about our com...

Page 3: ...e that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cables Only handle the power cord by the plug Never pull out the plug by tugging the power cord Keep the light clean Do not touch the light glasss with bare hands The product should always be installed with a secondary safety fixing On the projector base brink there is a hole for ...

Page 4: ...afety cord which can afford the weight ten times of lamp through Insurance hole for auxiliary hanging 4 Don t use the handle of the moving head light to fixed or lift Fitting The Lamp When replacing the bulb remove the plastic shell of the lamp head first Do not touch the bulb of the new lamp with bare hand so as not to influence the beam output Do not harm the sticking out point of the lamp durin...

Page 5: ...projector and another must be made with a 2 core screened cable with each core having at least a 0 5mm diameter Connection to and from the projector is via cannon 3 pin which are included with the projector XLR plugs and sockets The XLR s are connected as shown in the figure above Note Care should be taken to ensure that none of the pins touch the metallic body of the plug or each other The body o...

Page 6: ...nd corrupting the DMX control signals The DMX terminator is simply an XLR connector with a 120Ω ohm resistor connected across pins 2 and 3 which is then plugged into the output socket on the last projector in the chain The connections are illustrated below Function Set 1 Touch Operation Touch the Menu into the main menu as below Setting Info Factory CN 180 EN DMX Address Manual ...

Page 7: ...ne status receiving DMX signal from the controller or host automatic Host run automatically and send the DMXD signal from machine Voice control Receiving external sound or vibration run the built in application effect DMX address 1 512 Press OK button to enter edit state At this point is selected to one hundred according to the up down Key change address code Press the OK button once again and sel...

Page 8: ...current lamps and lanterns neither belongs to the state machine from machine shape not receiving DMX signal also does not belong to the host shape not send DMX signal Options Instructions Reset Click ok button after see confirmation dialog press the ok key once again after carry into the interface reset all motor The light bulb control ON OFF The color wheel 0 255 Press ok button to enter edit sta...

Page 9: ...alibration Channel Settings Can be set up channel switch Screen saver mode Pattern 1 According to address code Pattern 2 According to factory LOGO Pattern 3 No display reserve Bright time reset NO YES Maintenance To prolong the life of the projector some maintenance work has to be done to ensure the optical system in good condition If the projector does not function check the fuses on the power so...

Page 10: ...of the apparatus Trouble Shooting Problem Answer The moving head light doesn t switch on Check the fuse the power socket Replace the lamp Although shines but the moving head lamp doesn t accept the instruction of the controller Check the digital start address and also check the connection situation of the communication control line The moving head lamp only can work intermittently Inspect the powe...

Page 11: ...r7 Colour8 85 89 Colour8 90 94 Colour8 Colour9 95 99 Colour9 100 104 Colour9 Colour10 105 109 Colour10 110 114 Colour10 Colour11 115 119 Colour11 120 124 Colour11 Colour12 125 129 Colour12 130 134 Colour12 Colour13 135 139 Colour13 140 149 Colour13 Open 150 203 Forward flow From fast to slow 204 255 Reverse flow From slow to fast CH2 Shutter 0 3 Closed 4 103 Strobe pulse From slow to fast 104 107 ...

Page 12: ...55 Gobo11 shake From slow to fast 156 160 Open 161 205 Forward flow From fast to slow 206 210 Open 211 255 Reverse flow From slow to fast CH5 Prism1 0 255 000 019 invalid 020 075 Prism1 16 076 127 Prism2 24 16 8 128 255 Prism1Prism2 CH6 Prism1 Rot 0 127 Prism rotation positioning 128 191 Prism veering rotation from slow to fast 192 255 Prism reversion rotation from slow to fast Prism2 Rot 0 127 Pr...

Page 13: ...osition function 1Pcs 24 16 8 face rotation prism Bilateral rotation Prism superposition function Frost 1Pcs frost mirror Focus Linear focusing Multi color mirror 6 color mirror Dimmer 0 100 linear adjustment Strobe 0 5 9 times second Beam angle Parallel beam angel 0 1 9 Channel 16CH Control mode Standard DMX512 Automatic Sound and Master slave mode Pan X axis 540 automatically accurate positionin...

Reviews: