background image

 

SAFETY INSTRUCTIONS 

 

This  device  has  left  the  factory  in  perfect  condition.  In  order  to  maintain  this 
condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this user manual. 
 

When unpacking and before disposing of the carton, check there is no transportation damage before 

using the product. Should there be any damage caused by transportation, consult your dealer and do 

not use the apparatus. 

The device can be use indoors and outdoors, IP65.   

The device is not designed or intended to be mounted directly on to inflammable surfaces 

The device is only intended for installation, operation and maintenance by professional person. 

Do not device the beam onto inflammable surfaces, minimum distance is 5m. 

Avoid direct exposure to the light from the lamp. The light is harmful to the eye. 

Do not attempt to dismantle or modify the projector in any way. 

Electrical connection must only be carried out by qualified personnel. 

Before  installation,  ensure  that  the  voltage  and  frequency  of  power  supply  match  the  power 

requirements of the projector.   

It  is  essential  that  each  device  is  correctly  earthed  and  that  electrical  installation  conforms  to  all 

relevant standards. 

Do not connect this device to any other types of dimmer apparatus. 

Make  sure  that  the  power-cord  is  never  crimped  or  damaged  by  sharp  edges.  Never  let  the 

power-cord come into contact with other cables. Only handle the power-cord by the plug. Never pull 

out the plug by tugging the power-cord. 

LED  lens  shall  be  changed  if  they  have  become  visibly  damaged  to  such  an  extent  that  their 

effectiveness is impaired, for example by cracks or deep scratches. 

Exterior surface temperatures of the luminaire after 5 minutes operation is 60°C

when steady state 

is achieved 65°C. 

There is no user serviceable parts inside the projector, do not open the housing and never operate the 

device with the covers removed. 

If yo

u have any questions, don’t hesitate to consult your dealer or manufacturer.

 

Always disconnect from the mains, when the device is not in use or before 
cleaning it or before attempting any maintenance work !

 

Summary of Contents for MJ-2400-2IN1

Page 1: ...400 2IN1 User Manual PROFESSIONAL LED LIGHTING Thank you for choosing our mini LED blinder light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Page 2: ......

Page 3: ...ut by qualified personnel Before installation ensure that the voltage and frequency of power supply match the power requirements of the projector It is essential that each device is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp...

Page 4: ...d other demanding lighting occasions DMX 512 control connection The product has a DMX 512 input fitted with 3 pin XLR connectors Screened cables in compliance with EIA RS 485 specifications and the following characteristics must be used for connections 2 conductors plus screen 120Ohm impedance max transmission rate 250kBaud DMX 512 connection with DMX terminator For installations where the DMX cab...

Page 5: ...P99 CP01 CP99 Color change by Fade press UP and Down button change the Fade speed 6 DE99 DE01 DE99 Color change by Pulse press UP and Down button change the Pulse speed 7 BEBE Sound mode 8 O255 O000 O255 Warm white dimming by hand 9 Y255 Y000 Y255 White dimming by hand 10 n000 n001 n255 strobe speed press UP and Down button change the speed 11 ON OFF LED display On Off Cleaning and Maintenance We ...

Page 6: ...170 Snap Running 12 170 185 Fade Running 1 186 200 Fade Running 2 201 215 Fade Running 3 216 230 Pulse Running 231 255 Sound Running CH4 0 255 The speed of function from slowly to quickly CH5 0 255 WW1 dimming from dark to bright CH6 0 255 CW1 dimming from dark to bright CH7 0 255 WW2 dimming from dark to bright CH8 0 255 CW2 dimming from dark to bright CH9 0 255 WW3 dimming from dark to bright CH...

Page 7: ... 255 Main dimming from dark to bright CH2 0 255 Control strobe from slowly to quickly CH3 0 255 0 5 No function 6 20 Snap Running 1 21 35 Snap Running 2 36 50 Snap Running 3 51 65 Snap Running 4 66 80 Snap Running 5 81 95 Snap Running 6 96 105 Snap Running 7 106 110 Snap Running 8 111 125 Snap Running 9 126 140 Snap Running 10 141 155 Snap Running 11 156 170 Snap Running 12 170 185 Fade Running 1 ...

Page 8: ...ature 40 C Gross Weight 13 8 kg Package Size 480 x 450 x 300cm WARNING Please do NOT use the light under the water Please do NOT connect the power cable hand by hand over 4pcs Important notice Before open the LED blinder light and if you want to do the repair work please make sure the power source is at the separation condition Unceasingly carries on the product improvement about our company the p...