APPENDIX A: TECHNICAL SPECIFICATIONS
875DP/500DP/500HV DUAL PULSE
RESISTANCE WELDING POWER SUPPLIES
990-290
A-17
8
15
1
9
Figure A-7. CONTROL SIGNALS
Connector
The CONTROL SIGNALS connector ( figure A-5)
is a Viking DMRST15RA05CG (Unitek Peco PN
250-195). The mating connector, which included
in the shipping kit, is a TRW Cinch Connector
comprised of a DA-15P (Unitek Peco PN 250-199)
male connector and a DE-51210-1 (Unitek Peco
PN 250-200) plastic junction shell. The pin
assignments are listed below:
Pin
Function
1
Remote Weld Schedule Selection, Control Line 2
0
2
Remote Weld Schedule Selection, Control Line 2
1
3
Remote Weld Schedule Selection, Control Line 2
2
4
Remote Weld Schedule Selection, Control Line 2
3
5 No
Connection
6
Relay 2 Input
7 No
Connection
8
Relay 1 Input
9
Process and Charge Inhibit
10 Emergency
Stop
11
Signal and Chassis Ground
12 No
Connection
13
RELAY 2 Return
14 No
Connection
15
RELAY 1 Return
Emergency Stop
Emergency stop, or any other external function that should abort the welding sequence, can be
implemented by continuously shorting Pin 10 to Pin 11 of the CONTROL SIGNALS connector. If
either Pulse 1 or Pulse 2 has been initiated before the emergency stop signal occurs, that pulse will not
be interrupted. After that, no further operation can be initiated until the short has been removed.