CHAPTER 6: PROCESS DEFINITIONS AND WELD FUNCTIONS
875DP/500DP/500HV DUAL PULSE
RESISTANCE WELDING
POWER SUPPLIES
6-4
990-290
[HELP]
[RUN STATES] PAGE 1/6
REFERS TO A FRONT PANEL KEY.
USE
OR
TO SELECT SCHEDULES WHICH ARE
NUMBERED 0 THRU 15..
USE PROG TO MODIFY A SCHEDULE.
USE MENU TO DISPLAY THE MENU WHICH WILL
PROVIDE MORE INFORMATION.
HELP to Return
Next
[HELP]
[MACHINE STATES] PAGE 2/6
CHNG WILL CHANGE THE SCREEN FORMAT
TO INCLUDE THE STATUS OF EITHER THE
OUTPUT RELAYS OR THE WELD SENTRY.
SAVE, IS NOT USED IN THE RUN STATE.
Last
HELP to Return Next
HELP State
The power supply offers you context sensitive help when running or programming. Press [HELP]
whenever you have a question. Press [HELP] again to return to the original screen. For example, if you
press [HELP] from the RUN state, information on the function of the power supply keys will be
displayed as illustrated below:
Typical HELP screens. If there is more than one page of Help, the number of
pages will be displayed in the upper right-hand corner. Use
[
• •
] or [
• •
]
to
move from page to page. Press [HELP] to return to the previous state.
NO WELD State
The WELD/NO WELD switch is in the NO WELD position. The power supply will execute any weld
schedule, but the capacitor bank will not be discharged and no welding current will flow.
FIRE State
The firing switch in the weld head has closed and the welding sequence is proceeding.
Weld Function Field
The power supply allows you program 15 weld schedules. Each schedule can use one of its three weld
functions. There are two versions of the basic and rollspot functions: one for an air actuated weld head and
the other for a manually actuated weld head. The repeat function only applies to an air actuated weld head.