APPENDIX D: COMMUNICATION CODES
UNIFLOW
®
2 PULSED THERMODE CONTROL
990-228
D-7
PROFILE
“DR” Read
Profile #
2 Bytes
“DS” Set
ProfileNum (Profile number to be modified: 01 - 15)
2 Bytes
,
1
Byte
PreheatTemp (Preheat temperature: 060 - 999)
3 Bytes
,
1
Byte
ReflowTemp (Reflow temperature: 060 - 999)
3 Bytes
,
1
Byte
CoolTemp (Cool temperature: 060 - 999)
3 Bytes
,
1
Byte
PreheatTime (Preheat time: 000 – 999)
3 Bytes
,
1
Byte
RiseTime (Rise time: 00 – 99)
2 Bytes
,
1
Byte
ReflowTime (Reflow time: 000 – 999)
3 Bytes
,
1
Byte
CoarseRate (Coarse heating rate: 0 – 3)
1 Byte
0 = Very Slow
1 = Slow
2 = Medium
3 = Fast
27 Bytes Total
RELAY
“VR”
Read relay values
0 Bytes
“VS”
Relays1.on_off (0 = NORMALOPEN, 1 = NORMALCLOSED)
1 Byte
,
1
Byte
Relays1.when
1
Byte
REFLOW_TRIG = 0,
PREHEATON_TRIG = 1
ALARM_TRIG = 2
CLEANTHERM_TRIG = 3
REPLACETHERM_TRIG = 4
ENDOFREFLOW_TRIG = 5
HEADACTIVE_TRIG = 6
SYSTEMREADY_TRIG = 7
NOTACTIVE_TRIG = 8
,
1
Byte
Relays2.on_off (As above)
1 Byte
,
1
Byte
Relays2.when (As above)
1 Byte
,
1
Byte
Relays3.on_off (As above)
1 Byte
,
1
Byte
Relays3.when (As above)
1 Byte
,
1
Byte
Relays4.on_off (As above)
1 Byte
,
1
Byte
Relays4.when (As above)
1 Byte
15 Bytes Total