![Miyachi Unitek 1-292-01 Operator'S Manual Download Page 17](http://html1.mh-extra.com/html/miyachi-unitek/1-292-01/1-292-01_operators-manual_1812772017.webp)
CHAPTER 1: DESCRIPTION
UNIFLOW
®
2 PULSED THERMODE CONTROL
1-6
990-228
DATA EDIT Keys
The data edit keys allow you to edit the time and temperature
parameters of the heat profile on the graphic display. The
PREHEAT
,
RISE
,
REFLOW
and
COOL
keys are vertically
aligned with the profile heating states as displayed on the
graphic screen.
These keys are
only
active when the graphic screen is
displayed.
HEATING RATE Key
The
HEATING RATE
key brings up the
MANUAL TUNING
screen. This screen
screen allows you to go to the
SET COARSE HEATING RATE
and
SET FINE
HEATING RATE
heating rate capability to match the heat generating capability of
the thermode to minimize the temperature overshoot and undershoot. See
Chapter 3, Using Programming Functions
for details.
<MANUAL TUNING >
1. Set Coarse Heating Rate
:
MEDIUM
2. Set Fine Heating Rate
:
98%
NUMBER Select an item, Graph or Data
<SET COARSE HEATING RATE >
1. Very Slow
2. Slow
3. Medium
4. Fast
NUMBER Select ,
Page, Graph or Data
SETUP Key
This key brings up the
SETUP MENU
screen.
The
SETUP MENU
screen provides a menu of
operating characteristics for the Control.
< SETUP MENU >
1. HARDWARE SETUP
4. SYSTEM SECURITY
2. COMMUNICATIONS
5. COPY PROFILE
3. REFLOW SETUP
NUMBER Select an item, Graph or Data