knob located on the lid of the dispensing 
unit.

18 

Close the fluid dispensing hose shutoff 
valve, and carefully remove the adapter 
from the master cylinder, being careful 
not spill any brake fluid.

19 

Extract excess fluid or top-off the master 
cylinder as required, and replace the cap.

20 

Dispose of any hydraulic fluid remaining 
in the Dispenser. Do not store hydraulic 
fluid in the reservoir. Clean the dispens-
ing unit with denatured alcohol and store 
it properly.

21 

Test the brake or clutch system for leaks 
before driving the car.

The mityvac fluid dispensing system is 
appropriate for use to refill or top-off sealed 
automatic transmissions. Additional acces-
sories and adapters may be required and are 
available from Mityvac for performing this 
function.

NOTE

Do not allow the dispensing unit or 
master cylinder reservoir to run dry. Use 
the pressure relief valve to relieve the 
pressure and add new fluid if necessary

 



C AUTION

Lifetime “sealed” transmissions require 
the use of special manufacturer recom-
mended fluids. Use of any other fluids 
may cause severe damage to the trans-
mission and void the manufacturer’s 
warranty

Refilling sealed 
automatic 
transmissions

Unscrew the lid w/ pump from the reser-
voir, and fill to desired level with new vehi-
cle manufacturer’s recommended trans-
mission fluid.

Reinstall the lid w/ pump onto the 
reservoir.

Connect the fluid dispensing hose to the 
reservoir using the quick-connect coupler. 
Ensure the coupler sleeve snaps forward 
to lock the connection.

NOTE

There are two scales of volume on the 
reservoir. One scale indicates the 
volume when the lid w/ pump is 
removed and one when the lid w/ pump 
is installed. Be sure to note the 
appropriate scale.

 



C AUTION

If fluid is added above the MAX FILL line, 
the reservoir will overflow when the lid 
w/ pump is installed

Select the appropriate ATF refill adapter 
for the application and connect it to the 
output of the fluid dispensing hose.

Insert or connect the ATF refill adapter to 
the transmission.

While observing the pressure gauge, 
operate the pump to build pressure in the 
reservoir to the desired level, or until the 
proper amount of fluid has been dispensed.

NOTE

The shutoff valve installed in the fluid 
dispensing hose may be left open or 
closed. If left open, fluid will begin to 
flow as soon as the pump is operated. If 
closed, pressure will build in the 
reservoir as indicated on the gauge.

NOTE

Check the vehicle’s service manual to 
determine the proper method to check 
the transmission fluid level. Failure to 
follow the manufacturer’s recom-
mended procedure could result in 
under- or over-filling the transmission, 
causing severe transmission damage.

The pressure relief valve is designed 

to open and maintain maximum pres-
sure between 17 and 23 psi (1.2 and 1.6 
bar).

Continual operation of the pump is 

not required to maintain fluid flow. Fluid 
will continue to flow as long as there is 
pressure in the reservoir and the shutoff 
valve is open.

Do not exceed 25 psi (1.7 bar) pres-

sure in the reservoir. The relief valve 
should prevent this, but if it fails and the 
pressure exceeds 25 psi, immediately 
discontinue use and send the unit to an 
authorized service center for repair or 
replacement.

Once the proper amount of fluid has been 
dispensed, close the shutoff valve on the 
fluid dispensing hose and bleed off the 
pressure by tilting the pressure relief knob 
located on the lid.

Depending on the type of fluid and future 
intended use, store or empty the remain-
ing fluid from the reservoir.

Clean the unit with denatured alcohol or 
common household cleaners, and store it 
properly.

5

Summary of Contents for MV6400

Page 1: ...Date of issue January 2021 Form number 801193 Version 2 User and maintenance instructions Models MV6400 MV6410 MV6410A MV6412 MV6412A MV6840 Fluid dispensing system Indicates change...

Page 2: ...t is not designed to perform The procedures documented in this man ual are to serve as guidelines for the use of this equipment In addition to these guide lines always follow the manufacturer s rec om...

Page 3: ...voir MVA571 Fluid storage lid MVA576 1 2 gal reservoir MVA573 5 Gal Reservoir 822753 Hanging hook 801789 Latch Service kits Reference number Part number Description 1 801230 Lid with pump assembly 2 8...

Page 4: ...res ervoir and recheck the system for leaks 10 Once you ve proven all connections are secure and the master cylinder adapter does not leak remove the lid w pump WARNING Hydraulic brake fluid is hazard...

Page 5: ...e CAUTION If fluid is added above the MAX FILL line the reservoir will overflow when the lid w pump is installed 4 Select the appropriate ATF refill adapter for the application and connect it to the o...

Page 6: ...6...

Page 7: ...7...

Page 8: ...of the SKF Group SKF Group 2021 The contents of this publication are the copyright of the publisher and may not be reproduced even extracts unless prior written permission is granted Every care has be...

Page 9: ...ssion janvier 2021 Num ro de formulaire 801193 Version 2 Instructions d utilisation et de maintenance Mod les MV6400 MV6410 MV6410A MV6412 MV6412A MV6840 Syst me de distribution de fluide Indique le c...

Page 10: ...s curit de divers v hicules Toutefois les diff rences qui existent entre les marques et mod les de v hicules peu vent emp cher d utiliser ce mat riel comme pr vu N essayer en aucun cas de s en servir...

Page 11: ...de couvercle 4 801234 Manom tre 5 822561 Poign e de pompe 6 MVA5800A ATF refill kit MVA575 Flexible de distribution de fluide MVA570 Lance de distribution de fluide MVA6839 R servoir de purge sous pre...

Page 12: ...SEMENT Lle liquide de frein hydraulique est dan gereux et corrosif Prendre des pr cau tions pour ne pas y exposer les surfaces peintes et la peau lire et respecter les avertissements et instructions d...

Page 13: ...le ma tre cylindre selon le besoin et remettre le bouchon en place 20 Mettre au rebut toute huile hydraulique restant dans le distributeur Ne pas stocker d huile hydraulique dans le r s ervoir Nettoye...

Page 14: ...pet 4 Choisir l adaptateur de remplissage d huile transmission automatique correspon dant l application et le raccorder la sor tie du flexible de distribution de fluide 5 Introduire l adaptateur de re...

Page 15: ...7...

Page 16: ...nd soin a t apport l exactitude des informations donn es dans cette publication mais SKF d cline toute responsabilit pour les pertes ou dommages directs ou indirects d coulant de l utilisation du cont...

Page 17: ...Ausgabedatum Januar 2021 Formularnummer 801193 Ausf hrung 2 Benutzer und Wartungshinweise Modelle MV6400 MV6410 MV6410A MV6412 MV6412A MV6840 Fl ssigkeitsausgabesystem Zeigt eine nderung an...

Page 18: ...d praktische Weist zu warten Verschiedenheiten der Fahrzeugmarken und Modelle k nnen es jedoch unm glich machen das Ger t wie vorgesehen zu verwenden Man darf nicht versuchen das Ger t zu einerApplika...

Page 19: ...1 Gallone Beh lter 3 801233 Deckeldichtung 4 801234 Druckmessger t 5 822561 Pumpenhandgriff 6 MVA5800A ATF Nachf llset MVA575 Fl ssigkeits ausgabeschlauch MVA570 Fl ssigkeits ausgaberohr MVA6839 Druck...

Page 20: ...ssigkeitsmenge aus gegeben worden ist das Absperrventil schlie en und durch Kippen des Druck entlastungsschalters am Deckel den Druck ablassen 6 Je nach Art der Fl ssigkeit und der geplanten zuk nfti...

Page 21: ...ug gefahren wird Das Mityvac Fl ssigkeitsausgabesystem eig net sich zum Auff llen oder Nachf llen ver siegelter automatischer Getriebe Weitere Zusatzger te werden m glicherweise ben tigt und sind zur...

Page 22: ...ssigkeitsausgabes chlauch am Beh lter anbringen Sichers tellen dass die Anschlussh lse nach vorn schnappt und die Verbindung sichert HINWEIS Das Absperrventil im Fl ssigkeitsaus gabeschlauch kann offe...

Page 23: ...7...

Page 24: ...en mit gr ter Sorgfalt auf ihre Richtigkeit hin berpr ft Trotzdem kann keine Haftung f rVerluste oder Sch den irgendwelcherArt bernommen werden die sich mittelbar oder unmittelbar aus derVerwendung de...

Page 25: ...trucciones de uso y mantenimiento Modelos MV6400 MV6410 MV6410A MV6412 MV6412A MV6840 Sistema de distribuci n de fluido Fecha de emisi n enero 2021 N mero de formulario 801193 Versi n 2 Indica el camb...

Page 26: ...dise ado para efectuar el servicio en una variedad de veh culos de modo seguro y conveniente Sin embargo las diferencias de marcas y modelos de los veh culos puede hacer que sea imposible usar este eq...

Page 27: ...Empaquetadura de la tapa 4 801234 Man metro 5 822561 Palanca de la bomba 6 MVA5800A ATF refill kit MVA575 Manguera de distribuci n de fluidos MVA570 Varilla de distribu ci n de fluido MVA6839 Dep sito...

Page 28: ...g rese de que el manguito del acop lador vuelva por resorte hacia adelante para trabar la conexi n 7 Conecte el otro extremo de la manguera de distribuci n de fluido en el acoplador de conexi n r pida...

Page 29: ...pleto las transmisiones autom ticas selladas Tal vez sea necesario usar acceso rios y adaptadores adicionales y est n dis ponibles en Mityvac para realizar esta funci n Relleno de transmisiones autom...

Page 30: ...cionar la bomba de forma continua para mantener el caudal de fluido El fluido seguir fluyendo siempre que haya presi n en el dep sito y la v lvula de corte est abierta No sobrepase la presi n de 25 lb...

Page 31: ...7...

Page 32: ...2021 El contenido de esta publicaci n es propiedad de los editores y no puede reproducirse incluso parcial mente sin autorizaci n previa por escrito Se ha tenido el m ximo cuidado para garantizar la...

Reviews: